Detection of lines and boundaries in speckle images-application to medical ultrasound
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper describes an approach to boundary detection in ultrasound speckle based on an image enhancement technique. The enhancement algorithm works by filtering the image with "sticks," short line segments which are varied in orientation to achieve the maximum projected value at each point. The statistical properties of this approach have been described in an earlier paper; in this work we present three significant extensions to improve the performance of the basic method. First, we investigate the effect of varying the size and shape of the sticks. We show that these variations affect the performance of the algorithm in very fundamental ways, for example by making it more or less sensitive to thinner or more tightly curving boundaries. Second, we present a means of improving the performance of this technique by estimating the distribution function of the orientation of the line passing through each point. Finally, we show that images can be "stained" for easier visual interpretation by applying to each pixel a false color whose hue is related to the orientation of the most prominent line segment at that point. Examples are given to illustrate the performance of the different settings on a single image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004 · cited 1×
“, Canny, Roberts, or Sobel operators [2], [3] and related techniques such as [4], are ill-suited to detect the boundaries because they are not well modeled as step discontinuities in image intensity.”
BackgroundUse of the hough transformation to detect lines and curves in pictures
Duda, R. O., & Hart, P. E. (1972) · Communications of the ACM · doi:10.1145/361237.361242 · Cited by 6,633
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
“This was improved in [110] by using the Sticks algorithm [86] for edge enhancement as a pre-processing step before applying the PDAF/IMM algorithm.”
BackgroundMethodInfluentialAutomated breast cancer detection and classification using ultrasound images: A survey
Cheng, H. D., Shan, J., Ju, W., Guo, Y., & Zhang, L. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2009.05.012 · Cited by 728
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
Automatic breast ultrasound image segmentation: a survey
Xian, M., Zhang, Y., Cheng, H. D., Xu, F., Zhang, B., & Ding, J. (2018) · Pattern Recognition · doi:10.1016/j.patcog.2018.02.012 · Cited by 284
“[62] and some early works [58-61] detected tumor automatically based on low-level image features, e.”
BackgroundMethodInfluentialNonlinear Diffusion in Laplacian Pyramid Domain for Ultrasonic Speckle Reduction
Zhang, F., Yoo, Y. M., Koh, L. M., & Kim, Y. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.889735 · Cited by 203
“[9] proposed to filter an ultrasound image by utilizing short line segments in different angular orientations and selecting the orientation that is most”
Watershed segmentation for breast tumor in 2-D sonography
Huang, Y.-L., & Chen, D.-R. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.12.001 · Cited by 198
“Preprocessing procedures have been presented to improve the effectiveness of watersheds in various approaches (Detmer et al. 1990; Han et al. 1991; Choy and Jin 1996; Richard and Czerwinski 1999).”
MethodAutomatic ultrasound segmentation and morphology based diagnosis of solid breast tumors
Chang, R.-F., Wu, W.-J., Moon, W. K., & Chen, D.-R. (2005) · Breast Cancer Research and Treatment · doi:10.1007/s10549-004-2043-z · Cited by 198
“In the ultrasonic images, boundaries between tissue layers will appear as all sorts of lines; therefore, the edge detection problem can be modeled as a line process [21].”
BackgroundRecent trend in medical imaging modalities and their applications in disease diagnosis: a review
Abhisheka, B., Biswas, S. K., Purkayastha, B., Das, D., & Escargueil, A. (2023) · Multimedia Tools and Applications · doi:10.1007/s11042-023-17326-1 · Cited by 169
“It can be used to check blood flow rate, deformities in the abdomen, assist the biopsy process, breast lump, pelvic pain and fertility treatment[72, 73].”
Edge-guided boundary delineation in prostate ultrasound images
Pathak, S. D., Haynor, D. R., & Kim, Y. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897813 · Cited by 169
“grades the SNR by including more noise pixels along the stick templates [42].”
BackgroundCombining support vector machine with genetic algorithm to classify ultrasound breast tumor images
Wu, W.-J., Lin, S.-W., & Moon, W. K. (2012) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2012.07.004 · Cited by 99
Metadata
- Authors
- Czerwinski, R. N., Jones, D. L., & O'Brien, W. D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1999
- Volume
- 18
- Issue
- 2
- Pages
- 126-136
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2163674874
- Cited by
- 152
- References
- 2
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.