The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A model-based method for the reconstruction of total knee replacement kinematics
Open accessAbstract
A better knowledge of the kinematics behavior of total knee replacement (TKR) during activity still remains a crucial issue to validate innovative prosthesis designs and different surgical strategies. Tools for more accurate measurement of in vivo kinematics of knee prosthesis components are therefore fundamental to improve the clinical outcome of knee replacement. In the present study, a novel model-based method for the estimation of the three-dimensional (3-D) position and orientation (pose) of both the femoral and tibial knee prosthesis components during activity is presented. The knowledge of the 3-D geometry of the components and a single plane projection view in a fluoroscopic image are sufficient to reconstruct the absolute and relative pose of the components in space. The technique is based on the best alignment of the component designs with the corresponding projection on the image plane. The image generation process is modeled and an iterative procedure localizes the spatial pose of the object by minimizing the Euclidean distance of the projection rays from the object surface. Computer simulation and static/dynamic in vitro tests using real knee prosthesis show that the accuracy with which relative orientation and position of the components can be estimated is better than 1.5 degrees and 1.5 mm, respectively. In vivo tests demonstrate that the method is well suited for kinematics analysis on TKR patients and that good quality images can be obtained with a carefully positioning of the fluoroscope and an appropriate dosage. With respect to previously adopted template matching techniques, the present method overcomes the complete segmentation of the components on the projected image and also features the simultaneous evaluation of all the six degrees of freedom (DOF) of the object. The expected small difference between successive poses in in vivo sequences strongly reduces the frequency of false poses and both the operator and computation time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Brainerd, E. L., Baier, D. B., Gatesy, S. M., Hedrick, T. L., Metzger, K. A., Gilbert, S. L., & Crisco, J. J. (2010) · Journal of Experimental Zoology Part A: Ecological Genetics and Physiology · doi:10.1002/jez.589 · Cited by 524
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
Metadata
- Authors
- Zuffi, S., Leardini, A., Catani, F., Fantozzi, S., & Cappello, A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1999
- Volume
- 18
- Issue
- 10
- Pages
- 981-991
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2171035606
- Cited by
- 185
- References
- 1
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.