The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Edge-guided boundary delineation in prostate ultrasound images
Abstract
Accurate detection of prostate boundaries is required in many diagnostic and treatment procedures for prostate disease. In this paper, a new paradigm for guided edge delineation is described, which involves presenting automatically detected prostate edges as a visual guide to the observer, followed by manual editing. This approach enables robust delineation of the prostate boundaries, making it suitable for routine clinical use. The edge-detection algorithm is comprised of three stages. An algorithm called sticks is used to enhance contrast and at the same time reduce speckle in the transrectal ultrasound prostate image. The resulting image is further smoothed using an anisotropic diffusion filter. In the third stage, some basic prior knowledge of the prostate, such as shape and echo pattern, is used to detect the most probable edges describing the prostate. Finally, patient-specific anatomic information is integrated during manual linking of the detected edges. The algorithm was tested on 125 images from 16 patients. The performance of the algorithm was statistically evaluated by employing five expert observers. Based on this study, we found that consistency in prostate delineation increases when automatically detected edges are used as visual guide during outlining, while the accuracy of the detected edges was found to be at least as good as those of the human observers. The use of edge guidance for boundary delineation can also be extended to other applications in medical imaging where poor contrast in the images and the complexity in the anatomy limit the clinical usability of fully automatic edge-detection techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
An anatomic transcriptional atlas of human glioblastoma
Puchalski, R. B., Shah, N., Miller, J., Dalley, R., Nomura, S. R., Yoon, J.-G., Smith, K. A., Lankerovich, M., Bertagnolli, D., Bickley, K., et al. (2018) · Science · doi:10.1126/science.aaf2666 · Cited by 643
Segmentation of prostate boundaries from ultrasound images using statistical shape model
Shen, D., Zhan, Y., & Davatzikos, C. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809057 · Cited by 259
Carneiro, G., Georgescu, B., Good, S., & Comaniciu, D. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.928917 · Cited by 205
Automatic Estimation of Fetal Abdominal Circumference From Ultrasound Images
Jang, J., Park, Y., Kim, B., Lee, S. M., Kwon, J.-Y., & Seo, J. K. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2776116 · Cited by 63
Metadata
- Authors
- Pathak, S. D., Haynor, D. R., & Kim, Y.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2000
- Volume
- 19
- Issue
- 12
- Pages
- 1211-1219
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2163273992
- Cited by
- 169
- References
- 1
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.