Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan
Open accessAbstract
A computationally efficient technique is described for the simultaneous removal of ghosting and geometrical distortion artifacts in echo-planar imaging (EPI) utilizing a multiecho, gradient-echo reference scan. Nyquist ghosts occur in EPI reconstructions because odd and even lines of k-space are acquired with opposite polarity, and experimental imperfections such as gradient eddy currents, imperfect pulse sequence timing, B0 field inhomogeneity, susceptibility, and chemical shift result in the even and odd lines of k-space being offset by different amounts relative to the true center of the acquisition window. Geometrical distortion occurs due to the limited bandwidth of the EPI images in the phase-encode direction. This distortion can be problematic when attempting to overlay an activation map from a functional magnetic resonance imaging experiment generated from EPI data on a high-resolution anatomical image. The method described here corrects for geometrical distortion related to B0 inhomogeneity, gradient eddy currents, radio-frequency pulse frequency offset, and chemical shift effect. The algorithm for removing ghost artifacts utilizes phase information in two dimensions and is, thus, more robust than conventional one-dimensional methods. An additional reference scan is required which takes approximately 2 min for a matrix size of 64 X 64 and a repetition time of 2 s. Results from a water phantom and a human brain at 3 T demonstrate the effectiveness of the method for removing ghosts and geometric distortion artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sequence-independent segmentation of magnetic resonance images
Fischl, B., Salat, D. H., van der Kouwe, A. J. W., Makris, N., Ségonne, F., Quinn, B. T., & Dale, A. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.016 · Cited by 2,109
Visser, M., Jefferies, E., & Lambon Ralph, M. A. (2010) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21309 · Cited by 647
Schmithorst, V. J., Wilke, M., Dardzinski, B. J., & Holland, S. K. (2002) · Radiology · doi:10.1148/radiol.2221010626 · Cited by 417
Self-citationfMRI study of language lateralization in children and adults
Szaflarski, J. P., Holland, S. K., Schmithorst, V. J., & Byars, A. W. (2006) · Human Brain Mapping · doi:10.1002/hbm.20177 · Cited by 390
Self-citationSchmithorst, V. J., Wilke, M., Dardzinski, B. J., & Holland, S. K. (2005) · Human Brain Mapping · doi:10.1002/hbm.20149 · Cited by 382
Self-citation
Metadata
- Authors
- Schmithorst, V. J., Dardzinski, B. J., & Holland, S. K.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2001-06
- Volume
- 20
- Issue
- 6
- Pages
- 535-539
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2157560127
- Cited by
- 198
- References
- 0
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan. https://app.cochat.ai/papers/10.1109/42.929619
- The paper
- Schmithorst, V. J., Dardzinski, B. J., & Holland, S. K. (2001). Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.929619
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.