The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data
Abstract
In this paper, we present a novel algorithm for fuzzy segmentation of magnetic resonance imaging (MRI) data and estimation of intensity inhomogeneities using fuzzy logic. MRI intensity inhomogeneities can be attributed to imperfections in the radio-frequency coils or to problems associated with the acquisition sequences. The result is a slowly varying shading artifact over the image that can produce errors with conventional intensity-based classification. Our algorithm is formulated by modifying the objective function of the standard fuzzy c-means (FCM) algorithm to compensate for such inhomogeneities and to allow the labeling of a pixel (voxel) to be influenced by the labels in its immediate neighborhood. The neighborhood effect acts as a regularizer and biases the solution toward piecewise-homogeneous labelings. Such a regularization is useful in segmenting scans corrupted by salt and pepper noise. Experimental results on both synthetic images and MR data are given to demonstrate the effectiveness and efficiency of the proposed algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Fuzzy Relative of the ISODATA Process and Its Use in Detecting Compact Well-Separated Clusters
Dunn, J. C. (1973) · Journal of Cybernetics · doi:10.1080/01969727308546046 · Cited by 5,049
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“Such inhomogeneities have rendered conventional intensity-based classification of MR images very difficult, even with advanced techniques such as nonparametric, multichannel methods [5]–[7].”
MethodAdaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
A Convergence Theorem for the Fuzzy ISODATA Clustering Algorithms
Bezdek, J. C. (1980) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1980.4766964 · Cited by 980
Review of MR image segmentation techniques using pattern recognition
Bezdek, J. C., Hall, L. O., & Clarke, L. P. (1993) · Medical Physics · doi:10.1118/1.597000 · Cited by 953
Udupa, J. K., & Samarasekera, S. (1996) · Graphical Models and Image Processing · doi:10.1006/gmip.1996.0021 · Cited by 839
Fuzzy models for pattern recognition
Bezdek, J. C., & Pal, S. K. (1994) · Cited by 832
Adaptive fuzzy segmentation of magnetic resonance images
Pham, D. L., & Prince, J. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802752 · Cited by 805
Hall, L. O., Bensaid, A. M., Clarke, L. P., Velthuizen, R. P., Silbiger, M. S., & Bezdek, J. C. (1992) · IEEE Transactions on Neural Networks · doi:10.1109/72.159057 · Cited by 580
Estimating the bias field of MR images
Guillemaud, R., & Brady, M. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585758 · Cited by 329
An Image-Processing System for Qualitative and Quantitative Volumetric Analysis of Brain Images
Goldszal, A. F., Davatzikos, C., Pham, D. L., Yan, M. X. H., Bryan, R. N., & Resnick, S. M. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199809000-00030 · Cited by 295
Correction of intensity variations in MR images for computer-aided tissue classification
Dawant, B. M., Zijdenbos, A. P., & Margolin, R. A. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251128 · Cited by 291
Sources of intensity nonuniformity in spin echo images at 1.5 T
Simmons, A., Tofts, P. S., Barker, G. J., & Arridge, S. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320117 · Cited by 277
Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491417 · Cited by 260
Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction
Brinkmann, B. H., Manduca, A., & Robb, R. A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700729 · Cited by 213
Retrospective correction of intensity inhomogeneities in MRI
Meyer, C. R., Bland, P. H., & Pipe, J. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370400 · Cited by 176
Correction of intensity nonuniformity in MR images of any orientation
Wicks, D., Barker, G. J., & Tofts, P. S. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90023-7 · Cited by 155
Brandt, M. E., Bohant, T. P., Kramer, L. A., & Fletcher, J. M. (1994) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)90058-2 · Cited by 139
Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI
Tincher, M., Meyer, C. R., Gupta, R., et al. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232267 · Cited by 136
Image non-uniformity in magnetic resonance imaging: its magnitude and methods for its correction
Condon, B. R., Patterson, J. C., Wyper, D., Jenkins, A., & Hadley, D. M. (1987) · British Journal of Radiology · doi:10.1259/0007-1285-60-709-83 · Cited by 120
Phase and sensitivity of receiver coils in magnetic resonance imaging
McVeigh, E. R., Bronskill, M. J., & Henkelman, R. M. (1986) · Medical Physics · doi:10.1118/1.595967 · Cited by 98
Compensation of spatial inhomogeneity in MRI based on a parametric bias estimate
Brechbühler, C., Gerig, G., & Székely, G. J. (1996) · Lecture notes in computer science · doi:10.1007/bfb0046948 · Cited by 60
Bias field correction of breast MR images
Gilles, S., Brady, M., Declerck, J. M., et al. (1996) · Lecture notes in computer science · doi:10.1007/bfb0046950 · Cited by 38
Cited by
Fuzzy c-means clustering with spatial information for image segmentation
Chuang, K.-S., Tzeng, H.-L., Chen, S., Wu, J., & Chen, T.-J. (2006) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2005.10.001 · Cited by 1,323
Chen, S., & Zhang, D. (2004) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2004.831165 · Cited by 1,142
A Robust Fuzzy Local Information C-Means Clustering Algorithm
Krinidis, S., & Chatzis, V. (2010) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2040763 · Cited by 1,124
Cai, W., Chen, S., & Zhang, D. (2007) · Pattern Recognition · doi:10.1016/j.patcog.2006.07.011 · Cited by 1,088
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
Vovk, U., Pernus, F., & Likar, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.891486 · Cited by 851
Metadata
- Authors
- Ahmed, M. N., Yamany, S. M., Mohamed, N., Farag, A. A., & Moriarty, T.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-03
- Volume
- 21
- Issue
- 3
- Pages
- 193-199
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2115242586
- Cited by
- 1,792
- References
- 23
- FWCI
- 26.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.