The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Toward realistic soft-tissue modeling in medical simulation
Open accessAbstract
Most of today's medical simulation systems are based on geometric representations of anatomical structures that take no account of their physical nature. Representing physical phenomena and, more specifically, the realistic modeling of soft tissue will not only improve current medical simulation systems but will considerably enlarge the set of applications and the credibility of medical simulation, from neurosurgery planning to laparoscopic-surgery simulation. To achieve realistic tissue deformation, it is necessary to combine deformation accuracy with computer efficiency. On the one hand, biomechanics has studied complex mathematical models and produced a large amount of experimental data for accurately representing the deformation of soft tissue. On the other hand, computer graphics has proposed many algorithms for the real-time computation of deformable bodies, often at the cost of ignoring the physics principles. The author surveys existing models of deformation in medical simulation and analyze the impediments to combining computer-graphics representations with biomechanical models. In particular, the different geometric representations of deformable tissue are compared in relation to the tasks of real-time deformation, tissue cutting, and force-feedback interaction. Last, the author inspects the potential of medical simulation under the development of this key technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zienkiewicz, O. C. (1989) · Cited by 14,802
Terzopoulos, D., Platt, J., Barr, A., & Fleischer, K. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37427 · Cited by 1,693
(1952) · Archives of Ophthalmology · doi:10.1001/archopht.1952.00920010678023 · Cited by 819
Regularization of Inverse Visual Problems Involving Discontinuities
Terzopoulos, D. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767807 · Cited by 767
Biomechanics: Mechanical Properties of Living Tissues, 2nd ed.
Fung, Y. C., & Cowin, S. C. (1994) · Journal of Applied Mechanics · doi:10.1115/1.2901550 · Cited by 745
Deformation Constraints in a Mass-Spring Model to Describe Rigid Cloth Behavior
Provot, X. (1995) · Cited by 701
Extended free-form deformation: a sculpturing tool for 3D geometric modeling
Coquillart, S. (1990) · Proceedings of the 17th annual conference on Computer graphics and interactive techniques · doi:10.1145/97879.97900 · Cited by 615
A graphics-based software system to develop and analyze models of musculoskeletal structures
Delp, S. L., & Loan, J. P. (1995) · Computers in Biology and Medicine · doi:10.1016/0010-4825(95)98882-e · Cited by 561
pLebensohn, J. E. (1952) · American Journal of Ophthalmology · doi:10.1016/0002-9394(52)91076-3 · Cited by 505
Terzopoulos, D., & Fleischer, K. (1988) · The Visual Computer · doi:10.1007/bf01908877 · Cited by 475
Simulating facial surgery using finite element models
Koch, R. M., Gross, M. H., Carls, F. R., von Büren, D. F., Fankhauser, G., & Parish, Y. I. H. (1996) · Proceedings of the 23rd annual conference on Computer graphics and interactive techniques · doi:10.1145/237170.237281 · Cited by 352
Symmetry-seeking models and 3D object reconstruction
Terzopoulos, D., Witkin, A., & Kass, M. (1988) · International Journal of Computer Vision · doi:10.1007/bf00127821 · Cited by 284
Chen, D. T., & Zeltzer, D. L. (1992) · ACM SIGGRAPH Conference (SIGGRAPH) · doi:10.1145/133994.134016 · Cited by 236
The analysis of cardiac function: A continuum approach
Hunter, P. J., & Smaill, B. H. (1988) · Progress in Biophysics and Molecular Biology · doi:10.1016/0079-6107(88)90004-1 · Cited by 191
Interactively deformable models for surgery simulation
Cover, S. A., Ezquerra, N. F., O'Brien, J. F., Rowe, R., Gadacz, T., & Palm, E. (1993) · IEEE Computer Graphics and Applications · doi:10.1109/38.252559 · Cited by 188
A virtual environment and model of the eye for surgical simulation
Sagar, M. A., Bullivant, D., Mallinson, G. D., & Hunter, P. J. (1994) · Proceedings of the 21st annual conference on Computer graphics and interactive techniques - SIGGRAPH '94 · doi:10.1145/192161.192200 · Cited by 160
Chen, D. T., & Zeltzer, D. L. (1992) · ACM SIGGRAPH Computer Graphics · doi:10.1145/142920.134016 · Cited by 137
Young's modulus, density and material properties in cancellous bone over a large density range
Hodgskinson, R., & Currey, J. D. (1992) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00705371 · Cited by 129
Current and future applications of virtual reality for medicine
Satava, R. M., & Jones, S. B. (1998) · Proceedings of the IEEE · doi:10.1109/5.662873 · Cited by 123
Simulation of object and human skin formations in a grasping task
Gourret, J.-P., Thalmann, N. M., & Thalmann, D. (1989) · ACM SIGGRAPH Computer Graphics · doi:10.1145/74334.74335 · Cited by 121
Force feedback for surgical simulation
Chen, E., & Marcus, B. A. (1998) · Proceedings of the IEEE · doi:10.1109/5.662877 · Cited by 68
An integrated medical virtual reality program. The military application
Satava, R. M., & Jones, S. B. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.486724 · Cited by 14
Cited by
Recent development on computer aided tissue engineering — a review
Sun, W., & Lal, P. (2002) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(01)00116-x · Cited by 360
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Howe, R. D., & Matsuoka, Y. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.211 · Cited by 282
A Survey of Surgical Simulation: Applications, Technology, and Education
Liu, A., Tendick, F., Cleary, K., & Kaufmann, C. (2003) · Presence: Teleoperators and Virtual Environments · doi:10.1162/105474603322955905 · Cited by 279
Motion Planning: A Journey of Robots, Molecules, Digital Actors, and Other Artifacts
Latombe, J.-C. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067753 · Cited by 264
Metadata
- Authors
- Delingette, H.
- Venue
- Proceedings of the IEEE
- Published
- 1998-03
- Volume
- 86
- Issue
- 3
- Pages
- 512-523
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2125099770
- Cited by
- 303
- References
- 22
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.