The DOI matches its Crossref record.
In-fiber Bragg-grating temperature sensor system for medical applications
Abstract
A novel quasidistributed in-fiber Bragg grating (FBG) temperature sensor system has been developed for temperature proving in vivo in the human body for medical applications, e.g., hyperthermia treatment. This paper provides the operating principle of FBG temperature sensors and then the design of the sensor head. High-resolution detection of the wavelength-shifts induced by temperature changes are achieved using drift-compensated interferometric detection while the return signals from the FBG sensor array are demultiplexed with a simple monochromator which offers crosstalk-free wavelength-division-multiplexing (WDM). A "strain-free" probe is designed by enclosing the FBG sensor array in a protection sleeve. A four FBG sensor system is demonstrated and the experimental results are in good agreement with those obtained by traditional electrical thermocouple sensors. A resolution of 0.1/spl deg/C and an accuracy of /spl plusmn/0.2/spl deg/C over a temperature range of 30-60/spl deg/C have been achieved, which meet established medical requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In-fibre Bragg grating sensors
Rao, Y.-J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/4/002 · Cited by 1,606
Self-citationA review on various temperature-indication methods for Li-ion batteries
Raijmakers, L. H. J., Danilov, D. L., Eichel, R.-A., & Notten, P. H. L. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.02.078 · Cited by 424
Fiber Bragg Gratings for Medical Applications and Future Challenges: A Review
Lo Presti, D., Massaroni, C., Jorge Leitão, C. S., De Fátima Domingues, M., Sypabekova, M., Barrera, D., Floris, I., Massari, L., Oddo, C. M., Sales, S., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3019138 · Cited by 377
Review of Flexible Temperature Sensing Networks for Wearable Physiological Monitoring
Li, Q., Zhang, L., Tao, X., & Ding, X. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601371 · Cited by 354
Self-citationFiber grating sensors in medicine: Current and emerging applications
Mishra, V., Singh, N., Tiwari, U., & Kapur, P. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.02.045 · Cited by 275
Metadata
- Authors
- Rao, Y.-J., Webb, D. J., Jackson, D. A., Zhang, L., & Bennion, I.
- Venue
- Journal of Lightwave Technology
- Published
- 1997-05
- Volume
- 15
- Issue
- 5
- Pages
- 779-785
- ISSN
- 0733-8724 (ISSN-L)
- OpenAlex
- W2146855404
- Cited by
- 221
- References
- 0
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-fiber Bragg-grating temperature sensor system for medical applications. https://app.cochat.ai/papers/10.1109/50.580812
- The paper
- Rao, Y.-J., Webb, D. J., Jackson, D. A., Zhang, L., & Bennion, I. (1997). In-fiber Bragg-grating temperature sensor system for medical applications. Journal of Lightwave Technology. https://doi.org/10.1109/50.580812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.