The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Wavelet preprocessing for automated neural network detection of EEG spikes
Abstract
The purpose of this study was to investigate the feasibility of using a wavelet transforms (WT) as a preprocessor for an artificial neural network (ANN) based EEG spike detection system. The study aimed at decreasing the input size to the ANN detector, without decreasing the information content of the signal and degrading the detection performance. Since routine clinical EEG requires recordings from many channels (generally 32 or 64), input size becomes a critical design parameter for real-time multichannel spike detection systems. For a sliding window of 20 points, more than 600 input lines will be necessary for a 32-channel system, which is not easily manageable with current ANN technology. One approach to this problem is to use a single ANN module for each EEG channel and integrate the outputs across channel information with a second module. The authors have successfully developed a 16 channel prototype of such a system working in real-time. This system used a 20 point (100 ms) sliding time window and employed a floating point digital signal processor for real-time operation. Adding more channels to this system would be difficult for real-time operation. In addition, the authors' recent studies showed that the best detection performance is attained with a 30 point (150 ms) time window, further increasing the computational load. Thus, the development of a preprocessor to reduce the input size without significantly reducing the information content would be very helpful in developing large multichannel EEG spike detection systems.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Orthonormal bases of compactly supported wavelets
Daubechies, I. (1988) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160410705 · Cited by 8,190
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786
A glossary of terms most commonly used by clinical electroencephalographers
(1974) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(74)90099-6 · Cited by 532
Automatic recognition and quantification of interictal epileptic activity in the human scalp EEG
Gotman, J., & Gloor, P. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90063-8 · Cited by 424
A multistage system to detect epileptiform activity in the EEG
Dingle, A. A., Jones, R. D., Carroll, G. J., & Fright, W. R. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250582 · Cited by 199
Bertrand, O., Bohorquez, J., & Pernier, J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.277274 · Cited by 183
The use of the wavelet transform in the detection of an unknown transient signal
Frisch, M., & Messer, H. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119748 · Cited by 112
Automatic EEG spike detection: what should the computer imitate?
Webber, W. R., Litt, B., Lesser, R. P., Fisher, R. S., & Bankman, I. N. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90149-p · Cited by 106
Glover, J. R., Raghaven, N., Ktonas, P. Y., & Frost, J. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.24253 · Cited by 106
Pattern recognition of the electroencephalogram by artificial neural networks
Jandó, G., Siegel, R. M., Horváth, Z., & Buzsáki, G. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90082-7 · Cited by 92
Cited by
Deep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026
A review of wavelets in biomedical applications
Unser, M., & Aldroubi, A. (1996) · Proceedings of the IEEE · doi:10.1109/5.488704 · Cited by 754
Guo, L., Rivero, D., Dorado, J., Rabuñal, J. R., & Pazos, A. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.020 · Cited by 430
Guo, L., Rivero, D., & Pazos, A. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.08.030 · Cited by 399
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Metadata
- Authors
- Kalayci, T., & Ozdamar, O.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 1995
- Volume
- 14
- Issue
- 2
- Pages
- 160-166
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2138580453
- Cited by
- 264
- References
- 12
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wavelet preprocessing for automated neural network detection of EEG spikes. https://app.cochat.ai/papers/10.1109/51.376754
- The paper
- Kalayci, T., & Ozdamar, O. (1995). Wavelet preprocessing for automated neural network detection of EEG spikes. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/51.376754
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.