Simple model for piezoelectric ceramic/polymer 1-3 composites used in ultrasonic transducer applications
Abstract
A theoretical model is presented for combining parameters of 1-3 ultrasonic composite materials in order to predict ultrasonic characteristics such as velocity, acoustic impedance, electromechanical coupling factor, and piezoelectric coefficients. Hence, the model allows the estimation of resonance frequencies of 1-3 composite transducers. This model has been extended to cover more material parameters, and they are compared to experimental results up to PZT volume fraction nu of 0.8. The model covers calculation of piezoelectric charge constants d(33) and d(31). Values are found to be in good agreement with experimental results obtained for PZT 7A/Araldite D 1-3 composites. The acoustic velocity, acoustic impedance, and electromechanical coupling factor are predicted and found to be close to the values determined experimentally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Connectivity and piezoelectric-pyroelectric composites
Newnham, R. E., Skinner, D. P., & Cross, L. E. (1978) · Materials Research Bulletin · doi:10.1016/0025-5408(78)90161-7 · Cited by 1,916
Gururaja, T. R., Schulze, W. A., Cross, L. E., Newnham, R. E., Auld, B. A., & Wang, Y. J. (1985) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1985.31623 · Cited by 364
Cited by
Modeling 1-3 composite piezoelectrics: thickness-mode oscillations
Smith, W. A., & Auld, B. A. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.67833 · Cited by 832
Micromechanics predictions of the effective electroelastic moduli of piezoelectric composites
Dunn, M. L., & Taya, M. (1993) · International Journal of Solids and Structures · doi:10.1016/0020-7683(93)90058-f · Cited by 547
Piezoelectric single crystal ultrasonic transducers for biomedical applications
Zhou, Q., Lam, K. H., Zheng, H., Qiu, W., & Shung, K. K. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2014.06.001 · Cited by 442
Flexible Piezoelectric PMN–PT Nanowire-Based Nanocomposite and Device
Xu, S., Yeh, Y.-W., Poirier, G., McAlpine, M. C., Register, R. A., & Yao, N. (2013) · Nano Letters · doi:10.1021/nl400169t · Cited by 339
Chee, C. Y. K., Tong, L., & Steven, G. P. (1998) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9800900101 · Cited by 293
Metadata
- Authors
- Chan, H. L. W., & Unsworth, J.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1989-07
- Volume
- 36
- Issue
- 4
- Pages
- 434-441
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2134735488
- Cited by
- 425
- References
- 2
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.