The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Ultrasonic imaging of internal vibration of soft tissue under forced vibration
Abstract
An imaging system that can display both the amplitude and phase maps of internal vibration in soft tissues for forced low-frequency vibration is described. In this method, low-frequency sinusoidal vibration of frequency under several hundred hertz is applied from the surface of the sample and the resulting movement in it is measured from the Doppler frequency shift of the simultaneously transmitted probe ultrasonic waves. Basic experiments are carried out by using 3.0-MHz ultrasonic waves. The two-dimensional maps of the amplitude and phase of internal vibration are shown, and the velocities of vibration are measured for some samples as well as in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harris, C. M., Crede, C. E., & Trent, H. M. (1962) · Physics Today · doi:10.1063/1.3058391 · Cited by 1,023
(1996) · Choice Reviews Online · doi:10.5860/choice.33-6329 · Cited by 991
Pulsed Ultrasonic Doppler Blood-Flow Sensing
Baker, D. W. (1970) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1970.29558 · Cited by 371
Krouskop, T. A., Dougherty, D. R., & Vinson, F. S. (1987) · PubMed · Cited by 362
Oestreicher, H. L. (1951) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906828 · Cited by 257
Lerner, R. M., Parker, K. J., Holen, J., Gramiak, R., & Waag, R. C. (1988) · Acoustical Imaging · doi:10.1007/978-1-4613-0725-9_31 · Cited by 220
Measurement of soft tissue motion using correlation between A-scans
Dickinson, R. J., & Hill, C. R. (1982) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(82)90032-1 · Cited by 186
Ultrasonic study of in vivo kinetic characteristics of human tissues
Tristam, M., Barbosa, D. C., Cosgrove, D. O., Nassiri, D. K., Bamber, J. C., & Hill, C. R. (1986) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(86)90061-x · Cited by 83
Application of fourier analysis to clinical study of patterns of tissue movement
Tristam, M., Barbosa, D. C., Cosgrove, D. O., Bamber, J. C., & Hill, C. R. (1988) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(88)90026-9 · Cited by 65
Cited by
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Metadata
- Authors
- Yamakoshi, Y., Sato, J., & Sato, T.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1990-03
- Volume
- 37
- Issue
- 2
- Pages
- 45-53
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2125410406
- Cited by
- 474
- References
- 9
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.