The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
A new method for estimation of velocity vectors
Abstract
The paper describes a new method for determining the velocity vector of a remotely sensed object using either sound or electromagnetic radiation. The movement of the object is determined from a field with spatial oscillations in both the axial direction of the transducer and in one or two directions transverse to the axial direction. By using a number of pulse emissions, the inter-pulse movement can be estimated and the velocity found from the estimated movement and the time between pulses. The method is based on the principle of using transverse spatial modulation for making the received signal influenced by transverse motion. Such a transverse modulation can be generated by using apodization on individual transducer array elements together with a special focusing scheme. A method for making such a field is presented along with a suitable two-dimensional velocity estimator. An implementation usable in medical ultrasound is described, and simulated results are presented. Simulation results for a flow of 1 m/s in a tube rotated in the image plane at specific angles (0, 15, 35, 55, 75, and 90 degrees) are made and characterized by the estimated mean value, estimated angle, and the standard deviation in the lateral and longitudinal direction. The average performance of the estimates for all angles is: mean velocity 0.99 m/s, longitudinal S.D. 0.015 m/s, and lateral S.D. 0.196 m/s. For flow parallel to the transducer the results are: mean velocity 0.95 m/s, angle 0.10, longitudinal S.D. 0.020 m/s, and lateral S.D. 0.172 m/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
(1999) · Sensor Review · doi:10.1108/sr.1999.08719bae.001 · Cited by 6,021
Introduction to Fourier Optics
Sutton, P. (1996) · Quantum and Semiclassical Optics: Journal of the European Optical Society Part B · doi:10.1088/1355-5111/8/5/014 · Cited by 4,934
Durnin, J., Miceli, J. J., & Eberly, J. H. (1987) · Physical Review Letters · doi:10.1103/physrevlett.58.1499 · Cited by 3,667
Exact solutions for nondiffracting beams I The scalar theory
Durnin, J. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000651 · Cited by 2,605
Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
Jensen, J. A., & Svendsen, N. B. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.139123 · Cited by 2,493
Self-citationReal-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
Kasai, C., Namekawa, K., Koyano, A., & Omoto, R. (1985) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1985.31615 · Cited by 1,255
The Axicon: A New Type of Optical Element
McLeod, J. H. (1954) · Journal of the Optical Society of America · doi:10.1364/josa.44.000592 · Cited by 970
Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
Kasai, C., & Namekawa, K. (1985) · IEEE 1985 Ultrasonics Symposium · doi:10.1109/ultsym.1985.198654 · Cited by 573
High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering
Smith, S. W., Pavy, H. G., & von Ramm, O. T. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.68466 · Cited by 504
Cited by
Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography
Tanter, M., Bercoff, J., Sandrin, L., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041078 · Cited by 414
Udesen, J., Gran, F., Hansen, K., Jensen, J. A., Thomsen, C., & Nielsen, M. B. (2008) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.858 · Cited by 254
Self-citationDeep learning in ultrasound elastography imaging: A review
Li, H., Bhatt, M., Qu, Z., Zhang, S., Hartel, M. C., Khademhosseini, A., & Cloutier, G. (2022) · Medical Physics · doi:10.1002/mp.15856 · Cited by 47
An Angle-Independent Cross-Sectional Doppler Method for Flow Estimation in the Common Carotid Artery
van Knippenberg, L., van Sloun, R. J. G., Shulepov, S., Bouwman, R. A., & Mischi, M. (2020) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2020.2975315 · Cited by 11
Metadata
- Authors
- Jensen, J. A., & Munk, P.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1998-05
- Volume
- 45
- Issue
- 3
- Pages
- 837-851
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2122751187
- Cited by
- 428
- References
- 17
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new method for estimation of velocity vectors. https://app.cochat.ai/papers/10.1109/58.677749
- The paper
- Jensen, J. A., & Munk, P. (1998). A new method for estimation of velocity vectors. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/58.677749
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.