The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Towards a more rigorous and practical unit commitment by Lagrangian relaxation
Abstract
A Lagrangian relaxation algorithm for power system generator unit commitment is proposed. The algorithm proceeds in three phases. In the first phase, the Lagrangian dual of the unit commitment is maximized by standard subgradient techniques. The second phase finds a reserve-feasible dual solution, followed by a third phase of economic dispatch. A mathematically based, systematic and generally applicable procedure to search for a reserve-feasible dual solution is presented. The algorithm has been tested on systems of up to 100 units to be scheduled over 168 hours, giving reliable performance and low execution times. Both spinning and time-limited reserve constraints are treated.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Lagrangian Relaxation Method for Solving Integer Programming Problems
Fisher, M. L. (1981) · Management Science · doi:10.1287/mnsc.27.1.1 · Cited by 2,109
Generalized Lagrange Multiplier Method for Solving Problems of Optimum Allocation of Resources
Everett, H. (1963) · Operations Research · doi:10.1287/opre.11.3.399 · Cited by 1,274
A New Method for Unit Commitment at Electricite De France
Merlin, A., & Sandrin, P. (1983) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1983.318063 · Cited by 419
Cited by
A Computationally Efficient Mixed-Integer Linear Formulation for the Thermal Unit Commitment Problem
Carrion, M., & Arroyo, J. M. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.876672 · Cited by 1,731
Unit Commitment—A Bibliographical Survey
Padhy, N. P. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.821611 · Cited by 1,001
Genetic algorithm solution to unit commitment problem
Madraswala, H. S., & Deshpande, A. S. (2016) · 2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES) · doi:10.1109/icpeices.2016.7853075 · Cited by 963
Moghaddam, A. A., Seifi, A., Niknam, T., & Alizadeh Pahlavani, M. R. (2011) · Energy · doi:10.1016/j.energy.2011.09.017 · Cited by 630
Optimal response of a thermal unit to an electricity spot market
Arroyo, J. M., & Conejo, A. J. (2000) · IEEE Transactions on Power Systems · doi:10.1109/59.871739 · Cited by 536
A Novel Approach for Unit Commitment Problem via an Effective Hybrid Particle Swarm Optimization
Ting, T. O., Rao, M. V. C., & Loo, C. K. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.860907 · Cited by 446
Unit commitment by simulated annealing
Zhuang, F., & Galiana, F. D. (1990) · IEEE Transactions on Power Systems · doi:10.1109/59.49122 · Cited by 383
Self-citationNowak, M. P., & Römisch, W. (2000) · Annals of Operations Research · doi:10.1023/a:1019248506301 · Cited by 253
Metadata
- Authors
- Zhuang, F., & Galiana, F. D.
- Venue
- IEEE Transactions on Power Systems
- Published
- 1988-05
- Volume
- 3
- Issue
- 2
- Pages
- 763-773
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W1992390555
- Cited by
- 453
- References
- 3
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.