The DOI matches its Crossref record.
An adaptive controller for power system load-frequency control
Abstract
An adaptive controller is presented for load-frequency control of power systems. It uses a PI (proportional-integral) adaptation to satisfy the hyperstability condition for taking care of the parameter changes of the system. Only the available information on the states and output are required for the control. No explicit parameter identification is needed. The controller can be designed by using a reduced plant model to simplify the design without degrading the performance much, so it is very easy to implement practically. The simulation results indicate that good control performance can be obtained and that the performance is sensitive to the plant parameter changes. The control remains effective in the presence of generation rate constraints.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
Decentralized Sliding Mode Load Frequency Control for Multi-Area Power Systems
Mi, Y., Fu, Y., Wang, C., & Wang, P. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2277131 · Cited by 337
Metadata
- Authors
- Pan, C.-T., & Liaw, C.-M.
- Venue
- IEEE Transactions on Power Systems
- Published
- 1989
- Volume
- 4
- Issue
- 1
- Pages
- 122-128
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2129243551
- Cited by
- 367
- References
- 0
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An adaptive controller for power system load-frequency control. https://app.cochat.ai/papers/10.1109/59.32469
- The paper
- Pan, C.-T., & Liaw, C.-M. (1989). An adaptive controller for power system load-frequency control. IEEE Transactions on Power Systems. https://doi.org/10.1109/59.32469
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.