The DOI matches its Crossref record.
Contributions of individual generators to loads and flows
Abstract
Because of the introduction of competition in the electricity supply industry, it has become much more important to be able to determine which generators are supplying a particular load, how much use each generator is making of a transmission line and what is each generator's contribution to the system losses. This paper describes a technique for answering these questions which is not limited to incremental changes and which is applicable to both active and reactive power. Starting from a power flow solution, the technique first identifies the busses which are reached by power produced by each generator. Then it determines the sets of buses supplied by the same generators. Using proportionality assumption, it is then possible to calculate the contribution of each generator to the loads and flows. The applicability of the proposed technique is demonstrated using a 30-bus example.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tracing the flow of electricity
Bialek, J. (1996) · IEE Proceedings - Generation, Transmission and Distribution · doi:10.1049/ip-gtd:19960461 · Cited by 818
Impact of Network Reconfiguration on Loss Allocation of Radial Distribution Systems
Savier, J. S., & Das, D. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.905370 · Cited by 563
Wang, X.-F., Song, Y., & Irving, M. (2008) · Springer eBooks · doi:10.1007/978-0-387-72853-7 · Cited by 387
Real-time carbon accounting method for the European electricity markets
Tranberg, B., Corradi, O., Lajoie, B., Gibon, T., Staffell, I., & Andresen, G. B. (2019) · Energy Strategy Reviews · doi:10.1016/j.esr.2019.100367 · Cited by 200
Metadata
- Authors
- Kirschen, D., Allan, R., & Strbac, G.
- Venue
- IEEE Transactions on Power Systems
- Published
- 1997
- Volume
- 12
- Issue
- 1
- Pages
- 52-60
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2155284472
- Cited by
- 642
- References
- 0
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.