The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Identification of optimal operating point of PV modules using neural network for real time maximum power tracking control
Abstract
This paper presents an application of a neural network for the identification of the optimal operating point of PV modules for the real time maximum power tracking control. The output power from the modules depends on the environmental factors such as insolation, cell temperature, and so on. Therefore, accurate identification of optimal operating point and real time continuous control are required to achieve the maximum output efficiency. The proposed neural network has a quite simple structure and provides a highly accurate identification of the optimal operating point and also a highly accurate estimation of the maximum power from the PV modules.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An introduction to computing with neural nets
Lippmann, R. (1987) · IEEE ASSP Magazine · doi:10.1109/massp.1987.1165576 · Cited by 7,825
A contribution to the simulation and design optimization of photovoltaic systems
Jaboori, M. G., SAIED, M. M., & Hanafy, A. A. R. (1991) · IEEE Transactions on Energy Conversion · doi:10.1109/60.84313 · Cited by 82
Cited by
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425
Review of the maximum power point tracking algorithms for stand-alone photovoltaic systems
Salas, V., Olías, E., Barrado, A., & Lázaro, A. (2006) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2005.10.023 · Cited by 1,183
Masoum, M. A. S., Dehbonei, H., & Fuchs, E. F. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2002.805205 · Cited by 818
Novel maximum-power-point-tracking controller for photovoltaic energy conversion system
Kuo, Y.-C., Liang, T.-J., & Chen, J.-F. (2001) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.925586 · Cited by 691
Reza Reisi, A., Hassan Moradi, M., & Jamasb, S. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.11.052 · Cited by 690
Metadata
- Authors
- Hiyama, T., Kouzuma, S., & Imakubo, T.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 1995-06
- Volume
- 10
- Issue
- 2
- Pages
- 360-367
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2091114511
- Cited by
- 305
- References
- 2
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identification of optimal operating point of PV modules using neural network for real time maximum power tracking control. https://app.cochat.ai/papers/10.1109/60.391904
- The paper
- Hiyama, T., Kouzuma, S., & Imakubo, T. (1995). Identification of optimal operating point of PV modules using neural network for real time maximum power tracking control. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/60.391904
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.