The DOI matches its Crossref record.
In-line Sagnac interferometer current sensor
Abstract
The authors demonstrate for the first time a near shot noise limited in-line Sagnac interferometer current sensor. It is shown to have a number of advantages over the optical current sensors based on polarimetric Faraday and Faraday/Sagnac loop interferometer topologies, including lower sensitivity to environmental disturbances, less demanding optical components, and easy installation. Its application to power system measurements is also detailed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of the present status of optical fiber sensors
Lee, B. (2003) · Optical Fiber Technology · doi:10.1016/s1068-5200(02)00527-8 · Cited by 1,736
Current Sensing Techniques: A Review
Ziegler, S., Woodward, R. C., Iu, H. H.-C., & Borle, L. J. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2013914 · Cited by 774
Temperature and vibration insensitive fiber-optic current sensor
Bohnert, K., Gabus, P., Nehring, J., & Brandle, H. (2002) · Journal of Lightwave Technology · doi:10.1109/50.983241 · Cited by 331
Monitoring system for photovoltaic plants: A review
Madeti, S. R., & Singh, S. N. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.088 · Cited by 313
Metadata
- Authors
- Blake, J., Tantaswadi, P., & de Carvalho, R. T.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 1996
- Volume
- 11
- Issue
- 1
- Pages
- 116-121
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W1996529139
- Cited by
- 202
- References
- 0
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-line Sagnac interferometer current sensor. https://app.cochat.ai/papers/10.1109/61.484007
- The paper
- Blake, J., Tantaswadi, P., & de Carvalho, R. T. (1996). In-line Sagnac interferometer current sensor. IEEE Transactions on Power Delivery. https://doi.org/10.1109/61.484007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.