Real-time monitoring and dynamic thermal rating of power transmission circuits
The DOI matches its Crossref record.
Abstract
ANSI standards for power equipment, and a vast store of technical literature, describe various methods by which thermal ratings may be adjusted if actual weather conditions are known or if the "overload" is to be applied for a limited period of time. These methods have been given various names including dynamic thermal rating, on-line rating, and dynamic ratings to describe the process of adjusting thermal ratings of power equipment for actual weather conditions and actual electrical load patterns. This paper discusses in detail a project undertaken by the Electric Power Research Institute (RP 3022-7) as part of its research on Flexible AC Transmission. This project avoids dependence on temperature measurement, instead, calculating critical equipment component temperatures based solely on real-time weather and electrical current. Inexpensive, commercially available weather stations, digital data loggers, and IBM-compatible PC computers are combined with sophisticated thermal algorithms to yield a portable, flexible, instrumentation method which can rate several transmission circuits simultaneously, including underground cable, overhead lines, power transformers, current transformers, switches, bus, line traps, and circuit breakers. Useable increases of 5% to 15% in the thermal capacity of transmission equipment circuits result.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bollen, M., & Rönnberg, S. (2017) · Energies · doi:10.3390/en10091325 · Cited by 169
Forecasting for dynamic line rating
Michiorri, A., Nguyen, H.-M., Alessandrini, S., Bremnes, J. B., Dierer, S., Ferrero, E., Nygaard, B.-E., Pinson, P., Thomaidis, N., & Uski, S. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.134 · Cited by 168
“Another research group was active around Douglass and Edris at Power Technologies and the Electric Power Research Institute EPRI in the USA [25][9][26][27][28].”
BackgroundReliability Impact of Dynamic Thermal Rating System in Wind Power Integrated Network
Teh, J., & Cotton, I. (2016) · IEEE Transactions on Reliability · doi:10.1109/tr.2015.2495173 · Cited by 162
“First, the field applications of a DTR system have proven its reliability benefits in transmission networks [9], [10].”
BackgroundReview of dynamic line rating systems for wind power integration
Fernandez, E., Albizu, I., Bedialauneta, M. T., Mazon, A. J., & Leite, P. T. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.149 · Cited by 161
“1996 USA Georgia Power Company EPRI [34]”
Metadata
- Authors
- Douglass, D. A., & Edris, A.-A.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 1996-07
- Volume
- 11
- Issue
- 3
- Pages
- 1407-1418
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2080382979
- Cited by
- 197
- References
- 0
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time monitoring and dynamic thermal rating of power transmission circuits. https://app.cochat.ai/papers/10.1109/61.517499
- The paper
- Douglass, D. A., & Edris, A.-A. (1996). Real-time monitoring and dynamic thermal rating of power transmission circuits. IEEE Transactions on Power Delivery. https://doi.org/10.1109/61.517499
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.