Modeling of the thermal and hydraulic performance of plate fin, strip fin, and pin fin heat sinks-influence of flow bypass
The DOI matches its Crossref record.
Abstract
Tests have been conducted in a wind tunnel with seven types of heat sinks including plate fin, strip fin, and pin fin heat sinks. In the case of strip fin, and pin fin heat sinks, both in-line and staggered arrays have been studied. The pin fin heat sinks had circular and square cross-sections. For each type, tests were run with fin heights (H) of 10, 15, and 20 mm while the heat sink width (B) was kept constant and equal to 52.8 mm. In total, 42 different heat sinks were tested. The width of the wind tunnel duct (CB) was varied in such a way that results were obtained for B/CB=0.84, 0.53, and 0.33. The wind tunnel height (CH) was varied similarly, and data were recorded for H/CH=1, 0.67, and 0.33 while the duct Reynolds number was varied between 2000 through 16500. An empirical bypass correlation has been developed for the different fin designs. The correlation predicts the Nusselt number and the dimensionless pressure drop and takes into account the influence of duct height, duct width, fin height, fin thickness, and fin-to-fin distance. The correlation parameters are individual for each fin design. Further, a physical bypass model for plate fin heat sinks has been developed to describe the bypass effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Jonsson and Moshfegh [127] studied heat and flow performances for different types of extended surfaces including plate-fin, inline strip-fin, staggered strip-fin, inline circular-pin, staggered circular-pin, inline square-pin, and staggered square-pin. They correlated heat transfer and fluid-flow performances in terms of Nusselt number and dimensionless pressure drop ( ∆P * ) coeffi”
From Compact and microchannel heat exchangers: A comprehensive review of air-side friction factor and heat transfer correlations (2018) · cites this paper as [127]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 30
- 10.1115/1.3450859 · DOI
- 10.1115/1.3244472 · doi:10.1115/1.3244472
- 10.1115/1.3246965 · doi:10.1115/1.3246965
- 10.1115/1.3246883 · doi:10.1115/1.3246883
- 10.1109/33.49044 · doi:10.1109/33.49044
- Wirtz, 1993, Longitudinal fin heat sink performance in arrays of low-profile electronic packages, Adv. Electron. Packag., EEP-4–2, 809
- 10.1115/1.2905687 · doi:10.1115/1.2905687
- 10.1109/ITHERM.1994.342904 · doi:10.1109/itherm.1994.342904
- 10.1109/ITHERM.1996.534551 · doi:10.1109/itherm.1996.534551
- Jonsson, 2000, Influence of fin spacing, fin thickness, and inlet velocity on the performance of plate fin heat sinks under varying bypass conditions using CFD, Int. J. Heat Exchangers (IJHEX), 1, 177
- Jonsson, Modeling and characterization of plate fin heat sinks under bypass flow conditions using computational fluid dynamics methods, ASME J. Electron. Packag.
- 10.1115/1.3450654 · DOI
- 10.1016/0017-9310(79)90078-4 · DOI
- 10.1007/978-94-011-1082-2_24 · doi:10.1007/978-94-011-1082-2_24
- 10.1109/stherm.1994.288998 · doi:10.1109/stherm.1994.288998
- 10.1109/ITHERM.1996.534554 · doi:10.1109/itherm.1996.534554
- Kameoka, 1970, An experimental investigation on heat transfer by pin fins fixed on a plate, Bull Univ. Osaka Pref. A (Jpn.), 19, 17
- 10.1115/1.3239545 · DOI · Paper page
- Shaukatullah, Effect of pin fin heat sink size on thermal performance of surface mount plastic quad flat packs, 232
- 10.1115/1.2905702 · doi:10.1115/1.2905702
- Maudgal, Forced convection heat transfer from staggered pin fin arrays, 329, 35
- 10.1115/1.2826031 · doi:10.1115/1.2826031
- 10.1016/0017-9310(78)90200-4 · doi:10.1016/0017-9310(78)90200-4
- Jonsson, CFD modeling of the cooling performance of pin fin heat sinks under bypass flow conditions
- Jonsson, Influence of airflow bypass on the thermal performance and pressure drop of plate fin and pin fin heat sinks for electronics cooling, 44
- 10.1109/6144.833041 · doi:10.1109/6144.833041
- Jonsson, 2001, Turbulent forced convection air cooling of electronics with heat sinks under flow bypass conditions
- Butterbaugh, 1995, Effect of airflow bypass on the performance of heat sinks in electronic cooling, Adv. Electron. Packag., EEP-10–2, 843
- Kays, 1964, Compact Heat Exchangers
- 1993, StatSoft Inc.
Cited by
Thermal management of electronics: A review of literature
Anandan, S., & Ramalingam, V. (2008) · Thermal Science · doi:10.2298/tsci0802005a · Cited by 274
Qasem, N. A. A., & Zubair, S. M. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.06.104 · Cited by 134
Metadata
- Authors
- Jonsson, H., & Moshfegh, B.
- Venue
- IEEE Transactions on Components and Packaging Technologies
- Published
- 2001-06
- Volume
- 24
- Issue
- 2
- Pages
- 142-149
- ISSN
- 1521-3331
- Cited by
- 127
- References
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.