One-cycle control of switching converters
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A new large-signal nonlinear control technique is proposed to control the duty-ratio d of a switch such that in each cycle the average value of a switched variable of the switching converter is exactly equal to or proportional to the control reference in the steady-state or in a transient. One-cycle control rejects power source perturbations in one switching cycle; the average value of the switched variable follows the dynamic reference in one switching cycle; and the controller corrects switching errors in one switching cycle. There is no steady-state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with a constant frequency buck converter have demonstrated the robustness of the control method and verified the theoretical predictions. This new control method is very general and applicable to all types of pulse-width-modulated, resonant-based, or soft-switched switching converters for either voltage or current control in continuous or discontinuous conduction mode. Furthermore, it can be used to control any physical variable or abstract signal that is in the form of a switched variable or can be converted to the form of a switched variable.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple switching control method changes power converter into a current source
Deisch, C. W. (1978) · 1978 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.1978.7072368 · Cited by 320
Capel, A., Ferrante, G., O’Sullivan, D. L., & Weinberg, A. H. (1978) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1978.7072346 · Cited by 120
Advances in Switched-Mode Power Conversion Part II
Ćuk, S., & Middlebrook, R. D. (1983) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.1983.356698 · Cited by 69
Cited by
Positive output Luo converters: voltagelift technique
Luo, F. L. (1999) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19990291 · Cited by 234
Tan, S.-C., Lai, Y. M., Tse, C. K., Martinez-Salamero, L., & Wu, C.-K. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.905969 · Cited by 225
Nonlinear-carrier control for high-power-factor boost rectifiers
Maksimovic, D., Jang, Y., & Erickson, R. W. (1996) · IEEE Transactions on Power Electronics · doi:10.1109/63.506123 · Cited by 205
Multicarrier PWM With DC-Link Ripple Feedforward Compensation for Multilevel Inverters
Kouro, S., Lezana, P., Angulo, M., & Rodriguez, J. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911834 · Cited by 185
A review of single-phase PFC topologies based on the boost converter
Figueiredo, J. P. M., Tofoli, F. L., & Silva, B. L. A. (2010) · 2010 9th IEEE/IAS International Conference on Industry Applications - INDUSCON 2010 · doi:10.1109/induscon.2010.5740015 · Cited by 174
Metadata
- Authors
- Smedley, K. M., & Cuk, S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 1995-11
- Volume
- 10
- Issue
- 6
- Pages
- 625-633
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2098239527
- Cited by
- 648
- References
- 3
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One-cycle control of switching converters. https://app.cochat.ai/papers/10.1109/63.471281
- The paper
- Smedley, K. M., & Cuk, S. (1995). One-cycle control of switching converters. IEEE Transactions on Power Electronics. https://doi.org/10.1109/63.471281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.