The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
High-performance programmable AC power source with low harmonic distortion using DSP-based repetitive control technique
Abstract
This paper proposes a new control scheme based on a two-layer control structure to improve both the transient and steady-state responses of a closed-loop regulated pulse-width-modulated (PWM) inverter for high-quality sinusoidal AC voltage regulation. The proposed two-layer controller consists of a tracking controller and a repetitive controller. Pole assignment with state feedback has been employed in designing the tracking controller for transient response improvement, and a repetitive control scheme was developed in synthesizing the repetitive controller for steady-state response improvement. A design procedure is given for synthesizing the repetitive controller for PWM inverters to minimize periodic errors induced by rectifier-type nonlinear loads. The proposed control scheme has been realized using a single-chip digital signal processor (DSP) TMS320C14 from Texas Instruments. A 2-kVA PWM inverter has been constructed to verify the proposed control scheme. Total harmonic distortion (THD) below 1.4% for a 60-Hz output voltage under a bridge-rectifier RC load with a current crest factor of 3 has been obtained. Simulation and experimental results show that the DSP-based fully digital-controlled PWM inverter can achieve both good dynamic response and low harmonics distortion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digital control of dynamic systems
Franklin, G. F., Workman, M. L., & Powell, D. (1980) · International Linear Collider · Cited by 3,188
Digital control of dynamic systems
Anderson, B. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163502 · Cited by 1,690
Repetitive control system: a new type servo system for periodic exogenous signals
Hara, S., Yamamoto, Y., Omata, T., & Nakano, M. (1988) · IEEE Transactions on Automatic Control · doi:10.1109/9.1274 · Cited by 1,407
The internal model principle for linear multivariable regulators
Francis, B. A., & Wonham, W. M. (1975) · Applied Mathematics & Optimization · doi:10.1007/bf01447855 · Cited by 1,055
The internal model principle for linear multivariable regulators
Francis, B. A., & Wonham, W. M. (1975) · Applied Mathematics & Optimization · doi:10.1007/bf01448180 · Cited by 874
High Accuracy Control of a Proton Synchrotron Magnet Power Supply
Inoue, T., Nakano, M., Kubo, T., Matsumoto, S., & Baba, H. (1981) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)63938-7 · Cited by 430
Waveform compensation of PWM inverter with cyclic fluctuating loads
Haneyoshi, T., Kawamura, A., & Hoft, R. G. (1988) · IEEE Transactions on Industry Applications · doi:10.1109/28.6108 · Cited by 231
Cited by
Proportional-resonant controllers and filters for grid-connected voltage-source converters
Teodorescu, R., Blaabjerg, F., Liserre, M., & Loh, P. C. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060008 · Cited by 1,646
Survey on iterative learning control, repetitive control, and run-to-run control
Wang, Y., Gao, F., & Doyle, F. J. (2009) · Journal of Process Control · doi:10.1016/j.jprocont.2009.09.006 · Cited by 764
Digital Control in Power Electronics
Buso, S., & Mattavelli, P. (2006) · Synthesis lectures on power electronics · doi:10.2200/s00047ed1v01y200609pel002 · Cited by 535
Direct repetitive control of SPWM inverter for UPS purpose
Zhang, K., Kang, Y., Xiong, J., & Chen, J. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810846 · Cited by 396
Repetitive Compensation of Fluctuating DC Link Voltage for Railway Traction Drives
Ouyang, H., Zhang, K., Zhang, P., Kang, Y., & Xiong, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2105283 · Cited by 83
Metadata
- Authors
- Tzou, Y.-Y., Ou, R.-S., Jung, S.-L., & Chang, M.-Y.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 1997-07
- Volume
- 12
- Issue
- 4
- Pages
- 715-725
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2134809095
- Cited by
- 284
- References
- 7
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.