The DOI matches its Crossref record.
Model-based control of FES-induced single joint movements
Abstract
A crucial issue of functional electrical stimulation (FES) is the control of motor function by the artificial activation of paralyzed muscles. Major problems that limit the success of current FES systems are the nonlinearity of the target system and the rapid change of muscle properties due to fatigue. In this study, four different strategies, including an adaptive algorithm, to control the movement of the freely swinging shank were developed on the basis of computer simulations and experimentally evaluated on two subjects with paraplegia due to a complete thoracic spinal cord injury. After developing a nonlinear, physiologically based model describing the dynamic behavior of the knee joint and muscles, an open-loop approach, a closed-loop approach, and a combination of both were tested. In order to automate the individual adjustments cited above, we further evaluated the performances of an adaptive feedforward controller. The two parameters chosen for the adaptation were the threshold pulse width and the scaling factor for adjusting the active moment produced by the stimulated muscle to the fitness of the muscle. These parameters have been chosen because of their significant time variability. The first three controllers with fixed parameters yielded satisfactory result. An additional improvement was achieved by applying the adaptive algorithm that could cope with problems due to muscle fatigue, thus permitting on-line identification of critical parameters of the plant. Although the present study is limited to a simplified experimental setup, its applicability to more complex and functional movements can be expected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Functional Electrical Stimulation
(2008) · IEEE Control Systems · doi:10.1109/mcs.2007.914689 · Cited by 336
Zhang, D., Poignet, P., Widjaja, F., & Tech Ang, W. (2011) · Control Engineering Practice · doi:10.1016/j.conengprac.2010.08.009 · Cited by 88
Selfslagh, A., Shokur, S., Campos, D. S. F., Donati, A. R. C., Almeida, S., Yamauti, S. Y., Coelho, D. B., Bouri, M., & Nicolelis, M. A. L. (2019) · Scientific Reports · doi:10.1038/s41598-019-43041-9 · Cited by 78
Biomechanical loading as an alternative treatment for tremor: a review of two approaches
Rocon, E., Gallego, J. Á., Belda-Lois, J. M., Benito-León, J., & Pons, J. L. (2012) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.107 · Cited by 26
Advances in monitoring and control of refolding kinetics combining PAT and modeling
Pauk, J. N., Raju Palanisamy, J., Kager, J., Koczka, K., Berghammer, G., Herwig, C., & Veiter, L. (2021) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-021-11151-y · Cited by 25
Metadata
- Authors
- Ferrarin, M., Palazzo, F., Riener, R., & Quintern, J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2001-09
- Volume
- 9
- Issue
- 3
- Pages
- 245-257
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2138251506
- Cited by
- 231
- References
- 0
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Model-based control of FES-induced single joint movements. https://app.cochat.ai/papers/10.1109/7333.948452
- The paper
- Ferrarin, M., Palazzo, F., Riener, R., & Quintern, J. (2001). Model-based control of FES-induced single joint movements. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/7333.948452
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.