A microfabricated electrostatic haptic display for persons with visual impairments
The DOI matches its Crossref record.
Abstract
An electrostatic haptic display with three 7 x 7 electrode arrays of three different sizes was fabricated on a 4-in wafer using lithographic microfabrication techniques. The display utilizes electrostatic stimulation to generate a tactile sensation of texture on a scanning finger. The tactile sensation appeared to be a result of increased friction and vibration due to the electrostatic forces between the finger skin and the electrodes. Various spatial tactile patterns (lines, circles, squares, and triangles, etc.) can be presented on the display. Experiments of threshold, line separation, and pattern recognition were performed on subjects with visual impairments to study the spatial resolution and information transmission on arrays of variant electrode size and spacing. Two columns with two-column spacing can be resolved with 80% accuracy on the small array, for a spatial resolution of 5.8 mm in terms of edge-to-edge electrode distance. The overall percentages of correct recognition for the patterns were 68.3, 72.1, and 71.3% on the small, medium, and large arrays, respectively. While subject is an important factor for both threshold and pattern recognition, electrode size was statistically significant for threshold only. Frequency and duty cycle of the stimulation waveform did not show statistical significance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
TeslaTouch: electrovibration for touch surfaces
Bau, O., Poupyrev, I., Israr, A., & Harrison, C. (2010) · Proceedings of the 23nd annual ACM symposium on User interface software and technology · doi:10.1145/1866029.1866074 · Cited by 664
Microfabrication in Biology and Medicine
Voldman, J., Gray, M. L., & Schmidt, M. A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.401 · Cited by 344
Effect of Waveform on Tactile Perception by Electrovibration Displayed on Touch Screens
Vardar, Y., Guclu, B., & Basdogan, C. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2704603 · Cited by 130
“” Later, Tang and Beebe [11] performed experiments of detection threshold, line separation and pattern recognition with visually impaired subjects.”
BackgroundDesign Guideline for Developing Safe Systems that Apply Electricity to the Human Body
Kono, M., Takahashi, T., Nakamura, H., Miyaki, T., & Rekimoto, J. (2018) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3184743 · Cited by 63
Metadata
- Authors
- Tang, H., & Beebe, D. J.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1998
- Volume
- 6
- Issue
- 3
- Pages
- 241-248
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2113829449
- Cited by
- 129
- References
- 0
- FWCI
- 0.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfabricated electrostatic haptic display for persons with visual impairments. https://app.cochat.ai/papers/10.1109/86.712216
- The paper
- Tang, H., & Beebe, D. J. (1998). A microfabricated electrostatic haptic display for persons with visual impairments. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.712216
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.