The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
The quadruple-tank process: a multivariable laboratory process with an adjustable zero
Open accessAbstract
A multivariable laboratory process that consists of four interconnected water tanks is presented. The linearized dynamics of the system have a multivariable zero that is possible to move along the real axis by changing a valve. The zero can be placed in both the left and the right half-plane. In this way the quadruple-tank process is ideal for illustrating many concepts in multivariable control, particularly performance limitations due to multivariable right half-plane zeros. The location and the direction of the zero have an appealing physical interpretation. Accurate models are derived from both physical and experimental data and decentralized control is demonstrated on the process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
Isidori, A. (1989) · Springer eBooks · doi:10.1007/978-3-662-02581-9 · Cited by 7,869
Multivariable Feedback Control: Analysis and Design
Skogestad, S., & Postlethwaite, I. (1996) · Cited by 6,312
(2012) · SpringerReference · doi:10.1007/springerreference_117570 · Cited by 4,486
Virk, G. S. (1990) · Chemical Engineering Science · doi:10.1016/0009-2509(90)85041-b · Cited by 3,216
Network analysis and feedback amplifier design
Bode, H. W. (1945) · Virtual Defense Library (Ministerio de Defensa) · Cited by 3,119
Morari, M., & Zafiriou, E. (1988) · International Linear Collider · Cited by 2,735
(1987) · Lecture Notes in Control and Information Sciences · doi:10.1007/bfb0007371 · Cited by 2,518
Zames, G. (1981) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1981.1102603 · Cited by 2,373
N4SID: Subspace algorithms for the identification of combined deterministic-stochastic systems
Van Overschee, P., & De Moor, B. (1994) · Automatica · doi:10.1016/0005-1098(94)90230-5 · Cited by 1,979
Fundamental Limitations in Filtering and Control
Seron, M. M., Braslavsky, J. H., & Goodwin, G. C. (1997) · Communications and Control Engineering · doi:10.1007/978-1-4471-0965-5 · Cited by 664
(2003) · IEEE Control Systems · doi:10.1109/mcs.2003.1213600 · Cited by 407
Frequency Domain Properties of Scalar and Multivariable Feedback Systems
(1988) · Lecture Notes in Control and Information Sciences · doi:10.1007/bfb0044565 · Cited by 362
Trade-offs in linear control system design
Middleton, R. H. (1991) · Automatica · doi:10.1016/0005-1098(91)90077-f · Cited by 316
Cited by
A secure control framework for resource-limited adversaries
Teixeira, A., Shames, I., Sandberg, H., & Johansson, K. H. (2015) · Automatica · doi:10.1016/j.automatica.2014.10.067 · Cited by 1,187
Self-citationA survey of physics-based attack detection in cyber-physical systems
Giraldo, J., Urbina, D., Cardenas, A., Valente, J., Faisal, M., Ruths, J., Tippenhauer, N. O., Sandberg, H., & Candell, R. (2019) · ACM Computing Surveys · doi:10.1145/3203245 · Cited by 535
Wireless Network Design for Control Systems: A Survey
Park, P., Coleri Ergen, S., Fischione, C., Lu, C., & Johansson, K. H. (2018) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2780114 · Cited by 488
Self-citationAttack models and scenarios for networked control systems
Teixeira, A., Pérez, D., Sandberg, H., & Johansson, K. H. (2012) · Proceedings of the 1st international conference on High Confidence Networked Systems · doi:10.1145/2185505.2185515 · Cited by 471
Self-citationGhadimi, E., Teixeira, A., Shames, I., & Johansson, M. (2015) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2014.2354892 · Cited by 437
Metadata
- Authors
- Johansson, K. H.
- Venue
- IEEE Transactions on Control Systems Technology
- Published
- 2000-05
- Volume
- 8
- Issue
- 3
- Pages
- 456-465
- ISSN
- 1063-6536 (ISSN-L)
- OpenAlex
- W2150436340
- Cited by
- 1,104
- References
- 14
- FWCI
- 14.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.