CoChat

Quadruple adaptive observer of the core temperature in cylindrical Li-ion batteries and their health monitoring

Xinfan Lin, Stefanopoulou, A. G., Perez, H. E., Siegel, J. B., Yonghua Li, Anderson, R. D. · 2012 · 2012 American Control Conference (ACC)
Cited by 43

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Temperature monitoring is a critical issue for lithium ion batteries. Since only the surface temperature of the battery can be measured, a thermal model is needed to estimate the core temperature, which can be higher and hence more critical. In this paper, an on-line parameter identification scheme is designed for a cylindrical lithium ion battery thermal model, by which the parameters of the thermal model can be identified automatically. An adaptive observer is designed based on the on-line parameterization methodology and the closed loop architecture. A linear battery thermal model is explored first, where the internal resistance is assumed to be constant. The methodology is later extended to address temperature dependent internal resistance with non-uniform forgetting factors. The capability of the methodology to track the long term variation of the internal resistance is beneficial for battery health monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/acc.2012.6315386

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 43

Metadata

Authors
Lin, X., Stefanopoulou, A. G., Perez, H. E., Siegel, J. B., Li, Y., & Anderson, R. D.
Venue
2012 American Control Conference (ACC)
Publisher
IEEE
Published
2012-06
Pages
578-583
ISSN
0743-1619 (ISSN-L)
OpenAlex
W1967066288
Cited by
43
References
1
FWCI
6.40
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.