The DOI matches its Crossref record; 119 of the 119 references it cites were found in a registry or an index.
Energy Management and Optimization Methods for Grid Energy Storage Systems
Open accessAbstract
Today, the stability of the electric power grid is maintained through real time balancing of generation and demand. Grid scale energy storage systems are increasingly being deployed to provide grid operators the flexibility needed to maintain this balance. Energy storage also imparts resiliency and robustness to the grid infrastructure. Over the last few years, there has been a significant increase in the deployment of large scale energy storage systems. This growth has been driven by improvements in the cost and performance of energy storage technologies and the need to accommodate distributed generation, as well as incentives and government mandates. Energy management systems (EMSs) and optimization methods are required to effectively and safely utilize energy storage as a flexible grid asset that can provide multiple grid services. The EMS needs to be able to accommodate a variety of use cases and regulatory environments. In this paper, we provide a brief history of grid-scale energy storage, an overview of EMS architectures, and a summary of the leading applications for storage. These serve as a foundation for a discussion of EMS optimization methods and design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Model predictive control: Theory and practice—A survey
García, C. E., Prett, D. M., & Morari, M. (1989) · Automatica · doi:10.1016/0005-1098(89)90002-2 · Cited by 5,284
Ageing mechanisms in lithium-ion batteries
Vetter, J., Novák, P., Wagner, M. R., Veit, C., Möller, K.-C., Besenhard, J. O., Winter, M., Wohlfahrt-Mehrens, M., Vogler, C., & Hammouche, A. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.01.006 · Cited by 3,987
Demand Side Management: Demand Response, Intelligent Energy Systems, and Smart Loads
Palensky, P., & Dietrich, D. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2158841 · Cited by 2,927
Farhangi, H. (2010) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2009.934876 · Cited by 2,870
Optimal Control: Linear Quadratic Methods
Anderson, B. D. O., & Moore, J. B. (1979) · Cited by 2,823
Mohsenian-Rad, A.-H., Wong, V. W. S., Jatskevich, J., Schober, R., & Leon-Garcia, A. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2089069 · Cited by 2,744
Hatziargyriou, N., Asano, H., Iravani, R., & Marnay, C. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2007.376583 · Cited by 2,519
Demand response and smart grids – a survey
Siano, P. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.10.022 · Cited by 2,411
Energy storage systems—Characteristics and comparisons
IBRAHIM, H., ILINCA, A., & PERRON, J. (2008) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.01.023 · Cited by 2,331
Metadata
- Authors
- Byrne, R. H., Nguyen, T. A., Copp, D. A., Chalamala, B. R., & Gyuk, I.
- Venue
- IEEE Access
- Published
- 2018
- Volume
- 6
- Pages
- 13231-13260
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2748162992
- Cited by
- 406
- References
- 119
- FWCI
- 16.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Energy Management and Optimization Methods for Grid Energy Storage Systems. https://app.cochat.ai/papers/10.1109/access.2017.2741578
- The paper
- Byrne, R. H., Nguyen, T. A., Copp, D. A., Chalamala, B. R., & Gyuk, I. (2018). Energy Management and Optimization Methods for Grid Energy Storage Systems. IEEE Access. https://doi.org/10.1109/access.2017.2741578
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.