The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Novel Deep Learning Approach With Data Augmentation to Classify Motor Imagery Signals
Open accessAbstract
Brain-computer interface provides a new communication bridge between the human mind and devices, depending largely on the accurate classification and identification of non-invasive EEG signals. Recently, the deep learning approaches have been widely used in many fields to extract features and classify various types of data successfully. However, the deep learning approach requires massive data to train its neural networks, and the amount of data impacts greatly on the quality of the classifiers. This paper proposes a novel approach that combines deep learning and data augmentation for EEG classification. We applied the empirical mode decomposition on the EEG frames and mixed their intrinsic mode functions to create new artificial EEG frames, followed by transforming all EEG data into tensors as inputs of the neural network by complex Morlet wavelets. We proposed two neural networks-convolutional neural network and wavelet neural network-to train the weights and classify two classes of motor imagery signals. The wavelet neural network is a new type of neural network using wavelets to replace the convolutional layers. The experimental results show that the artificial EEG frames substantially improve the training of neural networks, and both two networks yield relatively higher classification accuracies compared to prevailing approaches. Meanwhile, we also verified the performance of our new proposed wavelet neural network model in the classification of steady-state visual evoked potentials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Thresholding of statistical maps in functional neuroimaging using the false discovery rate
Genovese, C. R., Lazar, N. A., & Nichols, T. (2002) · NeuroImage · doi:10.1006/nimg.2001.1037 · Cited by 4,923
Filter Bank Common Spatial Pattern Algorithm on BCI Competition IV Datasets 2a and 2b
Ang, K. K., Chin, Z. Y., Wang, C., Guan, C., & Zhang, H. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00039 · Cited by 1,264
Cited by
Altaheri, H., Muhammad, G., Alsulaiman, M., Amin, S. U., Altuwaijri, G. A., Abdul, W., Bencherif, M. A., & Faisal, M. (2023) · Neural Computing and Applications · doi:10.1007/s00521-021-06352-5 · Cited by 590
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Deep learning for motor imagery EEG-based classification: A review
Al-Saegh, A., Dawwd, S. A., & Abdul-Jabbar, J. M. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102172 · Cited by 437
Data augmentation for deep-learning-based electroencephalography
Lashgari, E., Liang, D., & Maoz, U. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108885 · Cited by 398
Brain-Controlled Robotic Arm System Based on Multi-Directional CNN-BiLSTM Network Using EEG Signals
Jeong, J.-H., Shim, K.-H., Kim, D.-J., & Lee, S.-W. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2981659 · Cited by 292
Metadata
- Authors
- Zhang, Z., Duan, F., Sole-Casals, J., Dinares-Ferran, J., Cichocki, A., Yang, Z., & Sun, Z.
- Venue
- IEEE Access
- Published
- 2019
- Volume
- 7
- Pages
- 15945-15954
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2913201307
- Cited by
- 193
- References
- 3
- FWCI
- 15.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.