Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 166

The DOI matches its Crossref record.

Fuzzy Logic Inverter Controller in Photovoltaic Applications: Issues and Recommendations

Open access
Hannan, Mahammad A., Ghani, Zamre ABD., Hoque, Md. Murshadul, Ker, Pin Jern, Hussain, Aini, Mohamed, Azah · 2019 · IEEE Access

Abstract

Fossil fuels and other conventional energy sources used to generate electricity are finite. Therefore, alternative energy sources should be pursued to meet present and future energy demands. The photovoltaic (PV) is a promising renewable energy source, especially for the remote areas. The PV is a DC power source that needs to be converted into usable AC power using an inverter. However, its nonlinearity and output fluctuation pose challenges in the design of PV based inverter. In this paper, a PV inverter controller system with the fundamentals of a fuzzy logic controller (FLC) and its applications and execution are reviewed. The different fuzzy controllers, inverter control algorithms, and switching techniques are studied. The findings indicate that the fuzzy logic controls have been gaining attention in the area of power control engineering, especially in inverter controller design for PV applications and generation. The FLC has a flexible and intelligent design, expedient user interface, easy computation and learning system, and combinations of different control algorithms. The FLC is also verifiable for completeness, redundancy, and consistency. However, finding the boundaries of membership functions and other rules of FLC requires manual tuning, long computation time, and considerable effort. This paper comprehensively reviews the FLC-based inverter control system to minimize PV output fluctuations, which cause inverter issues related to output harmonics, power factor, switching schemes, losses, and system implementation. The inverter system and its control strategy for future PV applications and generation require further research and development. Consequently, this review focuses on many factors and challenges and provides recommendations for designing capable and efficient inverter control systems for converting PV power to usable AC power. All the highlighted insights of this review will hopefully lead to increased efforts toward the development of the advanced inverter control systems for PV applications for AC loads and the utility grid.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2019.2899610

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Hannan, M. A., Ghani, Z. A., Hoque, M. M., Ker, P. J., Hussain, A., & Mohamed, A.
Venue
IEEE Access
Published
2019
Volume
7
Pages
24934-24955
ISSN
2169-3536 (ISSN-L)
OpenAlex
W2913985269
Cited by
166
References
0
FWCI
4.64
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fuzzy Logic Inverter Controller in Photovoltaic Applications: Issues and Recommendations. https://app.cochat.ai/papers/10.1109/access.2019.2899610
The paper
Hannan, M. A., Ghani, Z. A., Hoque, M. M., Ker, P. J., Hussain, A., & Mohamed, A. (2019). Fuzzy Logic Inverter Controller in Photovoltaic Applications: Issues and Recommendations. IEEE Access. https://doi.org/10.1109/access.2019.2899610

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.