CoChat

A Review of Data Centers Energy Consumption and Reliability Modeling

Open access
Ahmed, Kazi Main Uddin, Bollen, Math H. J., Alvarez, Manuel · 2021 · IEEE Access
Cited by 191

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Enhancing the efficiency and the reliability of the data center are the technical challenges for maintaining the quality of services for the end-users in the data center operation. The energy consumption models of the data center components are pivotal for ensuring the optimal design of the internal facilities and limiting the energy consumption of the data center. The reliability modeling of the data center is also important since the end-user’s satisfaction depends on the availability of the data center services. In this review, the state-of-the-art and the research gaps of data center energy consumption and reliability modeling are identified, which could be beneficial for future research on data center design, planning, and operation. The energy consumption models of the data center components in major load sections i.e., information technology (IT), internal power conditioning system (IPCS), and cooling load section are systematically reviewed and classified, which reveals the advantages and disadvantages of the models for different applications. Based on this analysis and related findings it is concluded that the availability of the model parameters and variables are more important than the accuracy, and the energy consumption models are often necessary for data center reliability studies. Additionally, the lack of research on the IPCS consumption modeling is identified, while the IPCS power losses could cause reliability issues and should be considered with importance for designing the data center. The absence of a review on data center reliability analysis is identified that leads this paper to review the data center reliability assessment aspects, which is needed for ensuring the adaptation of new technologies and equipment in the data center. The state-of-the-art of the reliability indices, reliability models, and methodologies are systematically reviewed in this paper for the first time, where the methodologies are divided into two groups i.e., analytical and simulation-based approaches. There is a lack of research on the data center cooling section reliability analysis and the data center components’ failure data, which are identified as research gaps. In addition, the dependency of different load sections for reliability analysis of the data center is also included that shows the service reliability of the data center is impacted by the IPCS and the cooling section.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2021.3125092

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 191

Metadata

Authors
Ahmed, K. M. U., Bollen, M. H. J., & Alvarez, M.
Venue
IEEE Access
Published
2021
Volume
9
Pages
152536-152563
ISSN
2169-3536 (ISSN-L)
OpenAlex
W3209312816
Cited by
191
References
4
FWCI
16.89
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Review of Data Centers Energy Consumption and Reliability Modeling. https://app.cochat.ai/papers/10.1109/access.2021.3125092
The paper
Ahmed, K. M. U., Bollen, M. H. J., & Alvarez, M. (2021). A Review of Data Centers Energy Consumption and Reliability Modeling. IEEE Access. https://doi.org/10.1109/access.2021.3125092

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.