Cited by 11Sensor Technology and Measurement SystemsAnalog and Mixed-Signal Circuit DesignGas Sensing Nanomaterials and Sensors

The DOI matches its Crossref record; the references it cites are not checked yet.

A Readout System for High Speed Interface of Wide Range Chemiresistive Sensor Array

Open access

Abstract

This paper aims at designing a compact readout system for chemiresistive sensor array with high speed and high accuracy. The proposed scheme is based on Resistance-to-Voltage (R-V) conversion and targets high density wide ranged chemiresistive sensor, with input resistance range of 1$\text{K}\Omega $- 1$\text{M}\Omega $and 0.1% sensitivity. The proposed approach uses Adaptive Reference Resistor Tuning (ARRT) technique implemented with a digital variable potentiometer to achieve a high accuracy without sacrificing the dynamic range and the speed. The system is implemented on a printed circuit board with a microcontroller and a 16-bit Analog-to-Digital Converter (ADC), and it has a compact dimension of 10 cm$\times6$cm, which is suitable for portable applications. The readout system works with a 5 V power supply, and the overall system power consumption is 150 mW. The system is designed to interface with a 118 sensor array and the experimental results achieved a satisfactory accuracy of 0.88%, as well as a measuring speed of 8.5 ms per sensor. Compared with existing approaches, our work targets a high density wide ranged chemiresistive sensor array and demonstrated high accuracy, high speed with the lowest circuit complexity, which is the novelty of this work.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2022.3170486

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

References 39 · Cited by 11

Research works printed but not linked: 43

  1. 10.1109/STC-CSIT.2018.8526672 · DOI
  2. 10.1109/ICACCM50413.2020.9213074 · DOI
  3. 10.1109/SYSoSE.2012.6384178 · DOI
  4. 10.1109/ROSE.2009.5355983 · DOI
  5. 10.1109/CDCIEM.2012.9 · DOI
  6. 10.1109/ICSENS.2004.1426115 · DOI
  7. 10.1109/ICSensT.2012.6461745 · DOI
  8. 10.1109/ACCESS.2019.2928875 · DOI
  9. 10.1109/ISMS.2012.139 · DOI
  10. 10.1109/ISPTS.2012.6260955 · DOI
  11. 10.1109/JSEN.2019.2929239 · DOI
  12. 10.1109/JSEN.2014.2333518 · DOI
  13. 10.1109/TIM.2017.2673001 · DOI
  14. 10.1515/mms-2016-0020 · DOI
  15. 10.1016/j.snb.2013.02.014 · DOI
  16. 10.1016/j.snb.2012.12.044 · DOI
  17. 10.1109/JSEN.2019.2955015 · DOI
  18. 10.1109/JSSC.2020.3017639 · DOI
  19. 10.1109/JSEN.2021.3134022 · DOI · Paper page
  20. 10.3390/s22051878 · DOI · Paper page
  21. 10.1109/TIM.2019.2928348 · DOI
  22. 10.1109/TIM.2017.2712918 · DOI
  23. 10.1109/TIM.2020.3034969 · DOI
  24. 10.21307/ijssis-2019-096 · DOI
  25. 10.1109/JSEN.2021.3107589 · DOI
  26. 10.1109/ICECA49313.2020.9297378 · DOI
  27. 10.1109/JSEN.2020.3042624 · DOI
  28. 10.1049/iet-cds.2014.0248 · DOI
  29. 10.1109/TCSII.2020.2999272 · DOI
  30. 10.3390/s20154180 · DOI
  31. 10.1007/978-3-030-95284-6 · DOI
  32. 10.1002/advs.202002014 · DOI
  33. 10.1016/j.snb.2014.05.075 · DOI
  34. 10.1109/ISOEN.2017.7968914 · DOI
  35. 10.3390/s131014214 · DOI · Paper page
  36. 10.3390/s90705099 · DOI
  37. 10.1021/nn505979j · DOI
  38. 10.3390/s20195642 · DOI
  39. 10.3390/chemosensors6040066 · DOI
  40. 2022, PSoC5LP Datasheet
  41. 2022, DPOT Datasheet
  42. 2022, OPAMP Datasheet
  43. 2022, ADC Datasheet

Metadata

Authors
Lakshminarayana, S., Park, Y., Park, H., & Jung, S.
Affiliations
The University of Texas at Arlington (US)
Venue
IEEE Access
Published
2022
Volume
10
Pages
45726-45735
ISSN
2169-3536 (ISSN-L)
OpenAlex
W4226021154
Cited by
11
References
39
Citations by year
2026: 3 · 2025: 4 · 2024: 2 · 2023: 2
FWCI
0.89
Type
journal article
Language
en
Open access
Locations
  • IEEE Access (publishedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Topics
  • Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
Keywords
readout system, high-density sensor arrays, high-speed measurement, low power consumption, portable electronics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review