The solid-state transformer concept: A new era in power distribution
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper considers the solid-state transformer concept as a viable alternative to the line frequency transformer in distribution circuits. The benefits of the concept are presented in terms of improvements to problem areas currently experienced on distribution networks as well as envisaged future or fringe benefits. Some barriers to universal acceptance of the concept are also identified, with the effects of these barriers analysed and discussed below.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ipakchi, A., & Albuyeh, F. (2009) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.931384 · Cited by 1,644 · cited 1×
“Having a controller with measuring capabilities in the network brings many advantages to the network, fitting into the idea of a smart grid [13].”
BackgroundAn actively cooled high power, high frequency transformer with high insulation capability
Heinemann, L. (2003) · APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335) · doi:10.1109/apec.2002.989270 · Cited by 135 · cited 1×
“This modular MV AC grid connected topology is also suggested for other systems, such as drives for the German 15 kV, 16 23 Hz train systems [10] and FACTS devices [11].”
Background
Cited by
Briz, F., Lopez, M., Rodriguez, A., & Arias, M. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2611648 · Cited by 171
“While PET designs using one, two, or three stages have been proposed [5], [8], a fully modular three-stage approach [Figure 1(a)] appears to be the most popular choice [2], [9]–[11].”
MethodFuture challenges and mitigation methods for high photovoltaic penetration: A survey
Olowu, T. O., Sundararajan, A., Moghaddami, M., & Sarwat, A. I. (2018) · Energies · doi:10.3390/en11071782 · Cited by 167
“The present challenges with SST applications include lower efficiency compared to the electromagnetic induction based transformers, complexities is in protection, balancing of voltage and currents, communication and control, and insulation for high voltage levels [148].”
BackgroundNew Bidirectional Intelligent Semiconductor Transformer for Smart Grid Application
Han, B.-M., Choi, N.-S., & Lee, J.-Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2284009 · Cited by 37
Details and implementation of a SiC-based solid state transformer prototype
Ramirez, J. M., Barrios, R. A., & Salome, B. J. (2017) · 2017 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America) · doi:10.1109/isgt-la.2017.8126690 · Cited by 6
“may be extended to a bidirectional system by replacing the passive rectifier with active systems [8]; (iii) Steimel et al.”
Background
Metadata
- Authors
- van der Merwe, J. W., & du T. Mouton, H.
- Venue
- AFRICON 2009
- Publisher
- IEEE
- Published
- 2009-09
- Pages
- 1-6
- OpenAlex
- W2170612052
- Cited by
- 72
- References
- 2
- FWCI
- 6.24
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The solid-state transformer concept: A new era in power distribution. https://app.cochat.ai/papers/10.1109/afrcon.2009.5308264
- The paper
- van der Merwe, J. W., & du T. Mouton, H. (2009). The solid-state transformer concept: A new era in power distribution. AFRICON 2009. https://doi.org/10.1109/afrcon.2009.5308264
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.