CoChat

Development of a 90 kW Bi-Directional DC-DC Converter for Power Dense Applications

Urciuoli, D.P., Tipton, C.W. · 2006 · Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06.
Cited by 49

The DOI matches its Crossref record.

Abstract

This paper presents the relevancy, design, and test results of a 90 kW continuous duty, three-phase, bi-directional, and DC-DC converter for hybrid electric vehicles. Nominal low-side and high-side voltages of 320 V and 600 V, respectively, were used. Continuous boost-mode operation at 90 kW and continuous buck-mode operation at 45 kW were demonstrated using 80 degC (inlet temperature) Castrol 399 oil coolant. The volumetric power density of the three-phase test-bed was 2.7 kW/l in boost-mode at a coolant temperature of 80 degC. Based on two-phase tests, the power density at a coolant temperature of 25 degC is projected to be 4.1 kW/l To increase power level and power density, custom IGBT modules have been built and tested. A design layout for a packaged four-phase converter, using the custom IGBTs, including sensors and control hardware, indicates that a volumetric power density of above 4 kW/l is feasible at an 80 degC coolant temperature

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/apec.2006.1620718

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Urciuoli, D. P., & Tipton, C. W.
Venue
Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06.
Publisher
IEEE
Published
2006-04-28
Pages
1375-1378
OpenAlex
W2161697730
Cited by
49
References
0
FWCI
6.37
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.