Three-Level Active Neutral-Point-Clamped (ANPC) Converter with Fault Tolerant Ability
The DOI matches its Crossref record.
Abstract
Compared with traditional three-level neutral-point-clamped converter, the recently proposed three-level active neutral-point-clamped (ANPC) converter can overcome the unequal loss distribution among semiconductor devices, and therefore result in increased output power or switching frequency. In industrial applications, fault tolerance of power electronics converters is very important considering system availability, safety and reliability. This paper presents the fault tolerant ability of three-level ANPC converter. Control schemes are proposed to keep the neutral-point voltage balanced and get stable and continuous output under single device fault for both open-circuit fault and short-circuit fault cases. Simulation results show the effectiveness of the fault tolerant ability of the three-level ANPC inverter under the presented control strategies, which are promising to carry on further experimental validation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872
A Survey on Neutral-Point-Clamped Inverters
Rodriguez, J., Bernet, S., Steimer, P. K., & Lizama, I. E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032430 · Cited by 1,813
Survey on Reliability of Power Electronic Systems
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192503 · Cited by 861
Survey on Fault Operation on Multilevel Inverters
Lezana, P., Pou, J., Meynard, T. A., Rodriguez, J., Ceballos, S., & Richardeau, F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032194 · Cited by 384
Catastrophic failure and fault-tolerant design of IGBT power electronic converters - an overview
Wu, R., Blaabjerg, F., Wang, H., Liserre, M., & Iannuzzo, F. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6699187 · Cited by 226
Metadata
- Authors
- Li, J., Huang, A. Q., Bhattacharya, S., & Tan, G.
- Venue
- 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition
- Publisher
- IEEE
- Published
- 2009-02
- Pages
- 840-845
- ISSN
- 1048-2334 (ISSN-L)
- OpenAlex
- W2165061661
- Cited by
- 54
- References
- 0
- FWCI
- 12.00
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Level Active Neutral-Point-Clamped (ANPC) Converter with Fault Tolerant Ability. https://app.cochat.ai/papers/10.1109/apec.2009.4802759
- The paper
- Li, J., Huang, A. Q., Bhattacharya, S., & Tan, G. (2009). Three-Level Active Neutral-Point-Clamped (ANPC) Converter with Fault Tolerant Ability. 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition. https://doi.org/10.1109/apec.2009.4802759
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.