A simply fall-detection algorithm using accelerometers on a smartphone
Abstract
Every year, several thousands of elderly people experience with falling accident. Falling is then a main problem about healthiness of elders. This paper tries to find out a simple algorithm to detect a fall. With less calculation, the device can quickly distinguish between a fall and a normal activity of daily living (ADL). As the smartphone technology is currently in very advance, it includes several sensors to come along. The sensors building in the smartphone are very useful in every field of measurements even in medical engineering. The tri-axial accelerometer is one sensor available on the smartphone and one application is to use for fall detection. From the study, the simple algorithm can be applied for fall detection by observing any change of x-, y-, or z-acceleration 10g within time limited obtaining from ADLs in terms of lying down. The advantages of using the smartphone as a fall detector are that it can alarm or call out for help. It is also getting cheap, widely used, and comfortable to use or mount.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Various sensors such as camera sensor, microphone sensor, accelerometer sensor, and gyroscope sensor were used in healthcare-based applications.
“Various sensors such as camera sensor [53–55], microphone sensor [56–58], accelerometer sensor [59–61], and gyroscope sensor [59, 62] were used in the healthcare-based applications.”
From Applications of Artificial Intelligence and Big Data Analytics in m-Health: A Healthcare System Perspective (2020) · cites this paper as [61]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cited by
Sorted by citations
khan, Z. F., & Alotaibi, S. R. (2020) · Journal of Healthcare Engineering · doi:10.1155/2020/8894694 · Cited by 235 · see citing works
- Authors
- Thammasat, E., & Chaicharn, J.
- Affiliations
- Thailand Institute of Scientific and Technological Research (TH)
- Thammasat University (TH)
- Venue
- The 5th 2012 Biomedical Engineering International Conference
- Publisher
- IEEE
- Published
- 2012-12
- Pages
- 1-4
- OpenAlex
- W2025348589
- Cited by
- 27
- References
- 0
- Citations by year
- 2025: 2 · 2024: 1 · 2021: 1 · 2020: 2 · 2019: 6 · 2018: 1 · 2017: 2 · 2016: 4 · 2015: 4 · 2014: 4
- FWCI
- 1.82
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Biomedical Engineering International Conference (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- fall detection, smartphone accelerometer, triaxial accelerometer, falls in older adults, activities of daily living, low-complexity algorithms, fall alarm
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review