Smart Jacket Design for Neonatal Monitoring with Wearable Sensors
Abstract
Critically ill new born babies admitted at the Neonatal Intensive Care Unit (NICU) are extremely tiny and vulnerable to external disturbance. Smart Jacket proposed in this paper is the vision of a wearable unobtrusive continuous monitoring system realized by body sensor networks (BSN) and wireless communication. The smart jacket aims for providing reliable health monitoring as well as a comfortable clinical environment for neonatal care and parent-child interaction. We present the first version of the neonatal jacket that enables ECG measurement by textile electrodes. We also explore a new solution for skin-contact challenges that textile electrodes pose. The jacket is expandable with new wearable technologies and has aesthetics that appeal to parents and medical staff. An iterative design process in close contact with the users and experts lead to a balanced integration of technology, user focus and aesthetics. We demonstrate the prototype and the experimental results obtained in clinical setting.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Textile-based sensors retain wired connections across the body, and their inability to support an intimate connection to the skin precludes reliable operation at clinical-grade levels of accuracy, particularly with motion.
“Although textile-based sensors are of interest, these technologies retain wired connections across the body, and their inability to support an intimate connection to the skin precludes reliable operation at clinical-grade levels of accuracy, particularly with motion (5–7).”
From Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care (2019) · cites this paper as [5]
Cited by
Sorted by citations
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807 · see citing works
Xu, S., Rwei, A. Y., Vwalika, B., Chisembele, M. P., Stringer, J. S. A., Ginsburg, A. S., & Rogers, J. A. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00001-7 · Cited by 57 · see citing works
A Ballistographic Approach for Continuous and Non-Obtrusive Monitoring of Movement in Neonates
Joshi, R., Bierling, B. L., Long, X., Weijers, J., Feijs, L., Van Pul, C., & Andriessen, P. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2875703 · Cited by 43 · see citing works
Self-citation
- Authors
- Bouwstra, S., Chen, W., Feijs, L., & Oetomo, S. B.
- Affiliations
- Eindhoven University of Technology (NL)
- Máxima Medisch Centrum (NL)
- Venue
- 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks
- Publisher
- IEEE
- Published
- 2009-06
- Pages
- 162-167
- ISSN
- 2376-8886 (ISSN-L)
- OpenAlex
- W2120803666
- Cited by
- 129
- References
- 0
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 7 · 2023: 8 · 2022: 2 · 2021: 8 · 2020: 8 · 2019: 10 · 2018: 10 · 2017: 7 · 2016: 8 · 2015: 7 · 2014: 6 · 2013: 8 · 2012: 10
- FWCI
- 21.11
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Wearable and Implantable Body Sensor Networks (publishedVersion)
- TU/e Research Portal (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- smart jacket, neonatal monitoring, wearable sensors, wireless body area networks, textile electrodes, ECG measurement, neonatal intensive care, wireless communication, skin contact, parent-child interaction, user-centered design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review