The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Accurate, Fast Fall Detection Using Gyroscopes and Accelerometer-Derived Posture Information
Abstract
Falls are dangerous for the aged population as they can adversely affect health. Therefore, many fall detection systems have been developed. However, prevalent methods only use accelerometers to isolate falls from activities of daily living (ADL). This makes it difficult to distinguish real falls from certain fall-like activities such as sitting down quickly and jumping, resulting in many false positives. Body orientation is also used as a means of detecting falls, but it is not very useful when the ending position is not horizontal, e.g. falls happen on stairs. In this paper we present a novel fall detection system using both accelerometers and gyroscopes. We divide human activities into two categories: static postures and dynamic transitions. By using two tri-axial accelerometers at separate body locations, our system can recognize four kinds of static postures: standing, bending, sitting, and lying. Motions between these static postures are considered as dynamic transitions. Linear acceleration and angular velocity are measured to determine whether motion transitions are intentional. If the transition before a lying posture is not intentional, a fall event is detected. Our algorithm, coupled with accelerometers and gyroscopes, reduces both false positives and false negatives, while improving fall detection accuracy. In addition, our solution features low computational cost and real-time response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm
Bourke, A. K., O’Brien, J. V., & Lyons, G. M. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.09.012 · Cited by 821
A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor
Bourke, A. K., & Lyons, G. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.12.001 · Cited by 509
Wearable Sensors for Reliable Fall Detection
Chen, J., Kwong, K., Chang, D., Luk, J., & Bajcsy, R. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1617246 · Cited by 443
Evaluation of a fall detector based on accelerometers: A pilot study
Lindemann, U., Hock, A., Stuber, M., Keck, W., & Becker, C. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351026 · Cited by 292
Monitoring behavior in home using a smart fall sensor and position sensors
Noury, N., Herve, T., Rialle, V., Virone, G., Mercier, E., Morey, G., Moro, A., & Porcheron, T. (2002) · 1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.00EX451) · doi:10.1109/mmb.2000.893857 · Cited by 244
Determination of simple thresholds for accelerometry-based parameters for fall detection
Kangas, M., Konttila, A., Winblad, I., & Jamsa, T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352552 · Cited by 202
SATIRE: a software architecture for smart AtTIRE
Ganti, R., Jayachandran, P., Abdelzaher, T., & Stankovic, J. A. (2006) · International Conference on Mobile Systems, Applications, and Services · doi:10.1145/1134680.1134693 · Cited by 153
Self-citationA system for monitoring posture and physical activity using accelerometers
Mathie, M. J., Basilakis, J., & Celler, B. G. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1019627 · Cited by 125
A smart sensor based on rules and its evaluation in daily routines
Noury, N., Barralon, P., Virone, G., Boissy, P., Hamel, M., & Rumeau, P. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280846 · Cited by 106
Preliminary evaluation of a full-time falling monitor for the elderly
Diaz, A. I., Prado-Velasco, M., Roa, L. M., Reina‐Tosina, J., & Sanchez, G.-D. G. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403637 · Cited by 71
Mobile anchor-free localization for wireless sensor networks
Xu, Y., Ouyang, Y., Le, Z., Ford, J., & Makedon, F. S. (2007) · doi:10.5555/1769087.1769094 · Cited by 21
Cited by
Personal Sensing: Understanding Mental Health Using Ubiquitous Sensors and Machine Learning
Mohr, D. C., Zhang, M., & Schueller, S. M. (2017) · Annual Review of Clinical Psychology · doi:10.1146/annurev-clinpsy-032816-044949 · Cited by 802
Challenges, issues and trends in fall detection systems
Igual, R., Medrano, C., & Plaza, I. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-66 · Cited by 654
USC-HAD: a daily activity dataset for ubiquitous activity recognition using wearable sensors
Zhang, M., & Sawchuk, A. A. (2012) · Proceedings of the 2012 ACM Conference on Ubiquitous Computing · doi:10.1145/2370216.2370438 · Cited by 554
Fusion of Smartphone Motion Sensors for Physical Activity Recognition
Shoaib, M., Bosch, S., Incel, O., Scholten, H., & Havinga, P. (2014) · Sensors · doi:10.3390/s140610146 · Cited by 552
UniMiB SHAR: A Dataset for Human Activity Recognition Using Acceleration Data from Smartphones
Micucci, D., Mobilio, M., & Napoletano, P. (2017) · Applied Sciences · doi:10.3390/app7101101 · Cited by 596
Metadata
- Authors
- Li, Q., Stankovic, J. A., Hanson, M. A., Barth, A. T., Lach, J., & Zhou, G.
- Venue
- 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks
- Publisher
- IEEE
- Published
- 2009-06
- Pages
- 138-143
- OpenAlex
- W2101286829
- Cited by
- 584
- References
- 11
- FWCI
- 22.08
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.