Accurate Activity Recognition Using a Mobile Phone Regardless of Device Orientation and Location
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper investigates two major issues in using a tri-axial accelerometer-embedded mobile phone for continuous activity monitoring, i.e. the difference in orientations and locations of the device. Two experiments with a total of ten test subjects performed six daily activities were conducted in this study: one with a device fixed on the waist in sixteen different orientations and another with three different device locations (i.e., shirt-pocket, trouser-pocket and waist) in two different device orientations. For handling with varying device orientations, a projection-based method for device coordinate system estimation has been proposed. Based on the dataset with sixteen different device orientations, the experimental results have illustrated that the proposed method is efficient for rectifying the acceleration signals into the same coordinate system, yielding significantly improved activity recognition accuracy. After signal transformation, the recognition results of signals acquired from different device locations are compared. The experimental results show that when the sensor is placed on different rigid body, different models are required for certain activities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Activity recognition using cell phone accelerometers
Kwapisz, J. R., Weiss, G. M., & Moore, S. A. (2011) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1964897.1964918 · Cited by 2,912 · cited 1×
“Since a mobile phone is being carried by users on daily basis, it is a suitable tool for continuous monitoring of user activities.”
MethodUsing gravity to estimate accelerometer orientation
Mizell, D. (2004) · Seventh IEEE International Symposium on Wearable Computers, 2003. Proceedings. · doi:10.1109/iswc.2003.1241424 · Cited by 212
Cited by
Stisen, A., Blunck, H., Bhattacharya, S., Prentow, T. S., Kjærgaard, M. B., Dey, A., Sonne, T., & Jensen, M. M. (2015) · Proceedings of the 13th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/2809695.2809718 · Cited by 714
On-body localization of wearable devices: An investigation of position-aware activity recognition
Sztyler, T., & Stuckenschmidt, H. (2016) · 2016 IEEE International Conference on Pervasive Computing and Communications (PerCom) · doi:10.1109/percom.2016.7456521 · Cited by 369
Performance Analysis of Smartphone-Sensor Behavior for Human Activity Recognition
Chen, Y., & Shen, C. (2017) · IEEE Access · doi:10.1109/access.2017.2676168 · Cited by 297
Human Activity Recognition Using Inertial Sensors in a Smartphone: An Overview
Sousa Lima, W., Souto, E., El-Khatib, K., Jalali, R., & Gama, J. (2019) · Sensors · doi:10.3390/s19143213 · Cited by 256
Efficient Human Activity Recognition Solving the Confusing Activities Via Deep Ensemble Learning
Zhu, R., Xiao, Z., Li, Y., Yang, M., Tan, Y., Zhou, L., Lin, S., & Wen, H. (2019) · IEEE Access · doi:10.1109/access.2019.2922104 · Cited by 86
Metadata
- Authors
- Henpraserttae, A., Thiemjarus, S., & Marukatat, S.
- Venue
- 2011 International Conference on Body Sensor Networks
- Publisher
- IEEE
- Published
- 2011-05
- Pages
- 41-46
- OpenAlex
- W2118503643
- Cited by
- 113
- References
- 2
- FWCI
- 6.22
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate Activity Recognition Using a Mobile Phone Regardless of Device Orientation and Location. https://app.cochat.ai/papers/10.1109/bsn.2011.8
- The paper
- Henpraserttae, A., Thiemjarus, S., & Marukatat, S. (2011). Accurate Activity Recognition Using a Mobile Phone Regardless of Device Orientation and Location. 2011 International Conference on Body Sensor Networks. https://doi.org/10.1109/bsn.2011.8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.