Real time muscle deformations using mass-spring systems
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this paper we propose a method to simulate muscle deformation in real-time, still aiming at satisfying visual results; that is, we are not attempting perfect simulation, but building a useful tool for interactive applications. Muscles are represented at 2 levels: the action lines and the muscle shape. The action line represents the force produced by a muscle on the bones, while the muscle shapes used in the simulation consist of a surface based model fitted to the boundary of medical image data. The algorithm to model muscle shapes is described. To physically simulate deformations, we used a mass-spring system with a new kind of springs called "angular springs" which were developed to control the muscle volume during simulation. Results are presented as examples at the end of the paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structural Changes in Muscle During Contraction: Interference Microscopy of Living Muscle Fibres
HUXLEY, A. F., & NIEDERGERKE, R. (1954) · Nature · doi:10.1038/173971a0 · Cited by 1,608 · cited 1×
“Regarding muscle contraction, when a muscle fiber shortens, the thin and thick myofilaments do not themselves get shorter, they rather slide across each other [14].”
BackgroundTerzopoulos, D., Platt, J., Barr, A., & Fleischer, K. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37427 · Cited by 1,110
Cited by
A Survey of Surgical Simulation: Applications, Technology, and Education
Liu, A., Tendick, F., Cleary, K., & Kaufmann, C. (2003) · Presence: Teleoperators and Virtual Environments · doi:10.1162/105474603322955905 · Cited by 279
Metadata
- Authors
- Nedel, L. P., & Thalmann, D.
- Venue
- Proceedings. Computer Graphics International (Cat. No.98EX149)
- Publisher
- IEEE Comput. Soc
- Published
- 2002-11-27
- Pages
- 156-165
- OpenAlex
- W1906058103
- Cited by
- 193
- References
- 2
- FWCI
- 7.92
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.