Human Activity Recognition from Sensor-Based Large-Scale Continuous Monitoring of Parkinson’s Disease Patients
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Smartphone-based assessments have been considered a potential solution to passively monitor gait and mobility in early-stage Parkinson's disease (PD) patients. In the Multiple Ascending Dose clinical trial of PRX002/RG7935, 44 PD patients and 35 age-and gender-matched healthy individuals performed smartphone-based assessments for up to 24 weeks and up to 6 weeks respectively. For "passive monitoring", subjects carried the smartphone with them as part of their daily routine, while sensors in the smartphone recording movement data continuously. In total, over 30,000 hours of passive monitoring data were collected. To classify the sensor signal into activity profiles, we built a Human Activity Recognition (HAR) model using Deep Neural Networks (DNN) trained on previously published data. The activity profiles of the participants determined by the HAR model showed significant differences between PD patients and healthy controls in the percentage of time walking and frequency in which subjects changed positions (sitting and standing). This combination of sensor data and machine learning-based activity profiling was shown to hold great promise for use in future clinical practice and drug development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Convolutional and LSTM Recurrent Neural Networks for Multimodal Wearable Activity Recognition
Ordóñez, F., & Roggen, D. (2016) · Sensors · doi:10.3390/s16010115 · Cited by 2,761 · cited 1×
“Similar structures have been used previously for HAR and have been shown to out-perform the traditional machine learning methods [3].”
Stisen, A., Blunck, H., Bhattacharya, S., Prentow, T. S., Kjærgaard, M. B., Dey, A., Sonne, T., & Jensen, M. M. (2015) · Proceedings of the 13th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/2809695.2809718 · Cited by 714
Research works printed but not linked: 4
- weiss, 2012, The Impact of Personalization on Smartphone-Based Activity Recognition, Proceedings of the AAAI-12 Workshop on Activity Context Representation Techniques and Languages
- 10.1186/1743-0003-9-75 · DOI
- 10.1145/2348543.2348580 · DOI · Paper page
- 10.1186/s12984-016-0154-5 · DOI · Paper page
Cited by
Deep learning for sensor-based activity recognition: A survey
Wang, J., Chen, Y., Hao, S., Peng, X., & Hu, L. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2018.02.010 · Cited by 2,014
Lipsmeier, F., Taylor, K. I., Kilchenmann, T., Wolf, D., Scotland, A., Schjodt‐Eriksen, J., Cheng, W., Fernandez‐Garcia, I., Siebourg‐Polster, J., Jin, L., et al. (2018) · Movement Disorders · doi:10.1002/mds.27376 · Cited by 266
“, time walking divided by total passive monitoring time), sit-to-stand transitions,(45,50,58) and turn speed(46,48-50,59,60) (Table 2).(50) One averaged summary score for each feature and participant was calculated over the whole observation period.”
BackgroundMethodSelf-citationSoleimani, E., & Nazerfard, E. (2021) · Neurocomputing · doi:10.1016/j.neucom.2020.10.056 · Cited by 146
Cheng, W.-Y., Lipsmeier, F., Scotland, A., Creagh, A., Kilchenmann, T., Jin, L., Schjodt-Eriksen, J., Wolf, D., Zhang-Schaerer, Y.-P., Garcia, I. F., et al. (2017) · 2017 IEEE Life Sciences Conference (LSC) · doi:10.1109/lsc.2017.8268169 · Cited by 13
“Details on model accuracy and robustness were previously investigated in [11].”
BackgroundSelf-citation
Metadata
- Authors
- Cheng, W.-Y., Scotland, A., Lipsmeier, F., Kilchenmann, T., Jin, L., Schjodt-Eriksen, J., Wolf, D., Zhang-Schaerer, Y.-P., Garcia, I. F., Siebourg-Polster, J., Soto, J., Verselis, L., Martin-Facklam, M., Boess, F., Koller, M., Grundman, M., Monsch, A., Postuma, R., Ghosh, A., Kremer, T., Taylor, K., Czech, C., Gossens, C., & Lindemann, M.
- Venue
- 2017 IEEE/ACM International Conference on Connected Health: Applications, Systems and Engineering Technologies (CHASE)
- Publisher
- IEEE
- Published
- 2017-07
- Pages
- 249-250
- OpenAlex
- W2748814859
- Cited by
- 54
- References
- 2
- FWCI
- 1.62
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human Activity Recognition from Sensor-Based Large-Scale Continuous Monitoring of Parkinson’s Disease Patients. https://app.cochat.ai/papers/10.1109/chase.2017.87
- The paper
- Cheng, W.-Y., Scotland, A., Lipsmeier, F., Kilchenmann, T., Jin, L., Schjodt-Eriksen, J., Wolf, D., Zhang-Schaerer, Y.-P., Garcia, I. F., Siebourg-Polster, J., Soto, J., Verselis, L., Martin-Facklam, M., Boess, F., Koller, M., Grundman, M., Monsch, A., Postuma, R., Ghosh, A., . . . Lindemann, M. (2017). Human Activity Recognition from Sensor-Based Large-Scale Continuous Monitoring of Parkinson’s Disease Patients. 2017 IEEE/ACM International Conference on Connected Health: Applications, Systems and Engineering Technologies (CHASE). https://doi.org/10.1109/chase.2017.87
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.