CoChat

Improved detection and classification of arrhythmias in noise-corrupted electrocardiograms using contextual information

Open access
Greenwald, S.D., Patil, R.S., Mark, R.G. · 2002 · [1990] Proceedings Computers in Cardiology
Cited by 124

The DOI matches its Crossref record.

Abstract

A novel approach for employing contextual information to process noisy electrocardiograms (ECGs) is described. The method is embedded in HOBBES, an expert arrhythmia analysis system. HOBBES is a post-processor to ARISTOTLE, a classical arrhythmia detector. ARISTOTLE and HOBBES were evaluated using a database of 35 half-hour records containing a mixture of supraventricular and ventricular ectopic activity. The HOBBES-assisted system performed dramatically better than ARISTOTLE alone in processing noisy ECGs.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/cic.1990.144257

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 124

Metadata

Authors
Greenwald, S. D., Patil, R. S., & Mark, R. G.
Venue
[1990] Proceedings Computers in Cardiology
Published
2002-12-04
Pages
461-464
ISSN
0276-6574 (ISSN-L)
OpenAlex
W1915489093
Cited by
124
References
0
FWCI
6.58
Type
conference paper
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved detection and classification of arrhythmias in noise-corrupted electrocardiograms using contextual information. https://app.cochat.ai/papers/10.1109/cic.1990.144257
The paper
Greenwald, S. D., Patil, R. S., & Mark, R. G. (2002). Improved detection and classification of arrhythmias in noise-corrupted electrocardiograms using contextual information. [1990] Proceedings Computers in Cardiology. https://doi.org/10.1109/cic.1990.144257

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.