Development of a new oscillometric blood pressure measurement system
The DOI matches its Crossref record.
Abstract
A new blood pressure measurement system was developed, based on the oscillometric method using a controlled linear deflation technique. The system was structured in order to make several tasks independent and specialized, thus allowing for future punctual developments. An oscillometric signal data base was formed according to the standard ANSI/AAMI/SP10-1992, using the manual auscultatory method as a reference to determine measurement techniques to be used. The correlation among several quantities such as reference blood pressure measurements, characteristic ratios, age, weight, height and arm circumference size, was studied. A new strategy to obtain systolic mean and diastolic pressures was an oscillometric pulse envelope, depending on parameters such as actual cuff pressure, mean pressure, pulse amplitude and arm circumference size. Mean differences of about -1,49 and 0,61 and standard deviations of 5,11 and 5,89 mmHg were obtained for systolic and diastolic pressure measurements, respectively. Moreover, a comparative study with commercial equipment was performed, with a simulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707
“1) Hardware and Algorithm Principles: The blood pressure measurements employ the standard oscillation method [24], [25] and [26].”
MethodPeter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Metadata
- Authors
- Moraes, J. C. T. B., Cerulli, M., & Ng, P. S.
- Venue
- Computers in Cardiology 1999. Vol.26 (Cat. No.99CH37004)
- Publisher
- IEEE
- Published
- 2003-01-20
- Pages
- 467-470
- ISSN
- 0276-6574 (ISSN-L)
- OpenAlex
- W2169276917
- Cited by
- 37
- References
- 0
- FWCI
- 4.65
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a new oscillometric blood pressure measurement system. https://app.cochat.ai/papers/10.1109/cic.1999.826009
- The paper
- Moraes, J. C. T. B., Cerulli, M., & Ng, P. S. (2003). Development of a new oscillometric blood pressure measurement system. Computers in Cardiology 1999. Vol.26 (Cat. No.99CH37004). https://doi.org/10.1109/cic.1999.826009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.