To make a secondary distribution system operate at its optimal performance, the use of an advanced power custom power device known as dynamic voltage restorer (DVR) has been proposed and researched. Optimum performance means acceptable voltage profile, increased reliability of supply, no overloading of cables and distribution transformers, the absence of unbalances in both voltage and current phases, and acceptable loss. This study involves the effective mitigation of power quality disturbance in secondary distribution networks as a result of voltage variation and voltage imbalance using a very effective power electronics-based custom power controller known as DVR. A DVR is connected between the secondary distribution transformer and the customer load along a feeder with a radial arrangement. An innovative new design-model of the DVR has been proposed and developed using dq0 controller and the proportional integral controller method. Model simulations were carried out using MATLAB/Simulink in Sim Power System tool box. The simulation results attest to the optimal performance of the proposed DVR configuration in mitigating the power quality problems, correcting voltage unbalance, and enhancing the voltage profile at the customer side to a statutory limit of ±5.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Large-scale integration and simultaneous charging of multiple EVs can create power quality challenges and have a high impact on existing electrical networks, disrupting standard operating condition by creating technical challenges such as voltage violations, transformer and line overloading, and increasing electrical losses.
“However, largescale integration and simultaneous charging of EVs can create power quality challenges for the distribution grid.”
From Hosting Capacity Assessment of South African Residential Low-Voltage Networks for Electric Vehicle Charging (2023) · cites this paper as [6]
A large amount of grid integration of solar PV and EVs can disrupt the standard operating condition by causing supply voltage violations, reverse power flow, transformer and line overloading, and an increase in electrical losses.
“However, a large amount of grid integration of solar PV and EVs can disrupt the standard operating condition by causing supply voltage violations, reverse power flow, transformer and lines overloading, and an increase in electrical losses [6].”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [6]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 17 · Cited by 72
- Authors
- Ogunboyo, P. T., Tiako, R., & Davidson, I. E.
- Affiliations
- University of KwaZulu-Natal (ZA)
- Durban University of Technology (ZA)
- Venue
- Canadian Journal of Electrical and Computer Engineering
- Published
- 2018
- Volume
- 41
- Issue
- 2
- Pages
- 105-115
- ISSN
- 0840-8688 (ISSN-L)
- OpenAlex
- W2891176154
- Cited by
- 72
- References
- 17
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 12 · 2023: 15 · 2022: 14 · 2021: 6 · 2020: 9 · 2019: 5 · 2018: 1
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Canadian Journal of Electrical and Computer Engineering (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- dynamic voltage restorer, voltage unbalance mitigation, voltage profile improvement, secondary distribution systems, custom power devices, power quality, PI controller, radial distribution feeders, voltage regulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review