Design and perceptual validation of performance measures for salient object segmentation
Abstract
Empirical evaluation of salient object segmentation methods requires i) a dataset of ground truth object segmentations and ii) a performance measure to compare the output of the algorithm with the ground truth. In this paper, we provide such a dataset, and evaluate 5 distinct performance measures that have been used in the literature practically and psychophysically. Our results suggest that a measure based upon minimal contour mappings is most sensitive to shape irregularities and most consistent with human judgements. In fact, the contour mapping measure is as predictive of human judgements as human subjects are of each other. Region-based methods, and contour methods such as Hausdorff distances that do not respect the ordering of points on shape boundaries are significantly less consistent with human judgements. We also show that minimal contour mappings can be used as the correspondence paradigm for Precision-Recall analysis. Our findings can provide guidance in evaluating the results of segmentation algorithms in the future.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Test Time Augmentation involves applying data augmentation transformations to the input image during test time and generating predictions for each augmented version.
“TTA involves ap- plying data augmentation transformations, such as rotations, flips, or color adjustments, to the input im- age during test time and generating predictions for each augmented version [24].”
Cited by
Sorted by citations
Salient Object Detection via Integrity Learning
Zhuge, M., Fan, D.-P., Liu, N., Zhang, D., Xu, D., & Shao, L. (2022) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2022.3179526 · Cited by 403 · see citing works
O.K., S., Riera-Marín, M., Galdran, A., López, J. G., Rodríguez-Comas, J., Piella, G., & Ballester, M. A. G. (2025) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2025.102547 · Cited by 11 · see citing works
- Authors
- Movahedi, V., & Elder, J. H.
- Affiliations
- York University (CA)
- ORCID
- Elder, James H.
- Venue
- 2010 IEEE Computer Society Conference on Computer Vision and Pattern Recognition - Workshops
- Publisher
- IEEE
- Published
- 2010-06
- Pages
- 49-56
- ISSN
- 2160-7508 (ISSN-L)
- OpenAlex
- W2171378720
- Cited by
- 469
- References
- 0
- Citations by year
- 2026: 8 · 2025: 25 · 2024: 29 · 2023: 36 · 2022: 46 · 2021: 52 · 2020: 53 · 2019: 49 · 2018: 36 · 2017: 36 · 2016: 35 · 2015: 29 · 2014: 19 · 2013: 12 · 2012: 2
- FWCI
- 4.39
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- 2009 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Visual Attention and Saliency Detection
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
- Keywords
- salient object segmentation, performance indicators, Hausdorff distance, region-based segmentation, perceptual validation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review