The DOI matches its Crossref record.
Analysis of the Impact of Electric Vehicle Charging Station on Power Quality Issues
Abstract
Although, number of Electric Vehicles (EV) in Bangladesh are limited compared to conventional vehicles but in near future, expecting that the EV penetration will be increased significantly. Owing to environmental & socio-economic benefits with reduction of fossil fuel use, EV markets are expanding. These EV have a major impact on the power grid & distribution networks and due to the consequences of huge power demand to recharge their batteries. Large number of EV charging station when integrates with the utility grid, it produces harmonics, affect the voltage profile, finally affects the power quality. In this paper, the impact of electric vehicle charging station in Bangladesh on power grid and distribution networks is analyzed in terms of power demand, harmonics, Voltage sag & swelling and transformer power loss. Also, the mitigation technique for reducing power quality disturbances is analyzed in this paper.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The THD is around 4.82 percent for single EVs attached to the device, 12.35 percent for three EVs, and 19.69 percent for five EVs with different configurations (Karmaker et al., 2019;Ahmed et al., 2021).”
From Optimal location of electric vehicle charging station and its impact on distribution network: A review (2022) · cites this paper as Karmaker et al., 2019
In the citing paper
“According to this study, the harmonic disturbances would be higher when the EV chargers are connected to the grid and distribution network.”
From Optimal location of electric vehicle charging station and its impact on distribution network: A review (2022) · cites this paper as Karmaker et al., 2019
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 11
- 10.1109/IFOST.2014.6991135 · DOI
- 10.1016/j.rser.2016.09.008 · DOI
- yusuf, 2018, Design and simulation of an Optimal Mini-Grid Solar-Diesel Hybrid Power Generation system in a remote Bangladesh, international journal of smart grid (ijsmartgrid), 2, 27
- 10.1051/rees/2016014 · DOI
- 10.1504/IJPSE.2017.084751 · DOI
- 10.1016/j.scs.2018.02.035 · DOI
- 10.3390/en10081217 · DOI
- 10.1016/j.enconman.2016.04.087 · DOI
- wetzer, 2018, Operation of transformers: Impact of harmonic loading on transformer losses, Transform magazine, 5, 74
- 0, PDB for bringing battery-run vehicles under tariff regulations
- das, 2013, Prospects of solar energy in Bangladesh, IOSR J Electr Electron Eng, 4, 46, 10.9790/1676-0454657 · DOI
Cited by
Sorted by citations
Ahmad, F., Iqbal, A., Ashraf, I., Marzband, M., & khan, I. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.01.180 · Cited by 533
Metadata
- Authors
- Karmaker, A. K., Roy, S., & Ahmed, M. R.
- Affiliations
- Dhaka University of Engineering & Technology (BD)
- Venue
- 2019 International Conference on Electrical, Computer and Communication Engineering (ECCE)
- Publisher
- IEEE
- Published
- 2019-02
- Pages
- 1-6
- OpenAlex
- W2938621424
- Cited by
- 174
- References
- 0
- Citations by year
- 2026: 7 · 2025: 19 · 2024: 39 · 2023: 43 · 2022: 22 · 2021: 28 · 2020: 10 · 2019: 6
- FWCI
- 26.26
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- International Conference on Electrical, Computer and Communication Engineering (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Vehicles and Infrastructure
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Keywords
- electric vehicle charging stations, power quality, harmonics, voltage sag, voltage swell, transformer losses, power demand, distribution networks, power quality mitigation, Bangladesh
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review