CoChat

Improvement of light load efficiency of Dual Active Bridge DC-DC converter by using dual leakage transformer and variable frequency

Guidi, G., Pavlovsky, M., Kawamura, A., Imakubo, T., Sasaki, Y. · 2010 · 2010 IEEE Energy Conversion Congress and Exposition
Cited by 80

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Dual Active Bridge (DAB) topology performs very well for converter output/input ratio close to transformer ratio. However, if a considerable deviation from the transformer ratio is required the conversion efficiency drops significantly. The approach presented in this paper uses variable AC link reactance to improve the DAB performance during operation at light load. The variable reactance is obtained by using a variable frequency in combination with so-called dual leakage transformer. Simple phase-shift control is used, and the switching frequency is varied in order to minimize the peak transformer current. In addition to that, the dual leakage transformer proposed in this paper has a winding configuration yielding a high leakage inductance at low currents and low leakage inductance at high currents. A fully operational prototype was built, demonstrating a power density of 7.1 kW/Liter with forced air cooling, and a peak efficiency at rated 4 kW load equal to 96.6 %. The presented variable reactance approach resulted in more than 10 % efficiency improvement over the conventional DAB design in the most critical point.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/ecce.2010.5617909

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Guidi, G., Pavlovsky, M., Kawamura, A., Imakubo, T., & Sasaki, Y.
Venue
2010 IEEE Energy Conversion Congress and Exposition
Publisher
IEEE
Published
2010-09
Pages
830-837
OpenAlex
W2007091476
Cited by
80
References
2
FWCI
3.49
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.