Switching control strategy to extend the ZVS operating range of a Dual Active Bridge AC/DC converter
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A switching control strategy to extend the zero-voltage-switching (ZVS) operating range of a Dual Active Bridge (DAB) AC/DC converter to the entire input-voltage interval and the full power range is proposed. The converter topology consists of a DAB DC/DC converter, receiving a rectified AC line voltage via a synchronous rectifier. The DAB comprises a primary side half bridge and secondary side full bridge, linked by a high-frequency isolation transformer and inductor. Using conventional control strategies, the soft-switching boundary conditions are exceeded at the higher voltage conversion ratios of the AC input interval. A novel pulse-width-modulation strategy to fully eliminate these boundaries and its analysis are presented in this paper, allowing increased performance (in terms of efficiency and stresses). Additionally, by using a half bridge / full bridge configuration, the number of active components is reduced. A prototype converter was constructed and experimental results are given to validate the theoretical analyses and practical feasibility of the proposed strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 1×
“It was shown in [7] that for high voltage MOSFET transistors low currents (0 A Icomm 2 A) are insufficient to recharge the parasitic drain to source capacitors within a 200 ns dead-time interval, leading to increased switching losses.”
Background
Cited by
Optimal ZVS Modulation of Single-Phase Single-Stage Bidirectional DAB AC–DC Converters
Everts, J., Krismer, F., Van den Keybus, J., Driesen, J., & Kolar, J. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2292026 · Cited by 501
Self-citationCombined Phase Shift and Frequency Modulation of a Dual Active Bridge AC-DC Converter with PFC
Jauch, F., & Biela, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2515850 · Cited by 229
Sfakianakis, G. E., Everts, J., & Lomonova, E. A. (2015) · 2015 Tenth International Conference on Ecological Vehicles and Renewable Energies (EVER) · doi:10.1109/ever.2015.7112939 · Cited by 47
Self-citationSingle-Phase Isolated Bidirectional AC-DC Battery Charger for Electric Vehicle – Review
Nassary, M., Orabi, M., Ghoneima, M., & El-Nemr, M. K. (2019) · 2019 International Conference on Innovative Trends in Computer Engineering (ITCE) · doi:10.1109/itce.2019.8646528 · Cited by 28
“9 Two stage bidirectional converter, [26], [27].”
Method
Metadata
- Authors
- Everts, J., Van den Keybus, J., & Driesen, J.
- Venue
- 2011 IEEE Energy Conversion Congress and Exposition
- Publisher
- IEEE
- Published
- 2011-09
- Pages
- 4107-4114
- OpenAlex
- W2169686957
- Cited by
- 37
- References
- 1
- FWCI
- 3.04
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Switching control strategy to extend the ZVS operating range of a Dual Active Bridge AC/DC converter. https://app.cochat.ai/papers/10.1109/ecce.2011.6064328
- The paper
- Everts, J., Van den Keybus, J., & Driesen, J. (2011). Switching control strategy to extend the ZVS operating range of a Dual Active Bridge AC/DC converter. 2011 IEEE Energy Conversion Congress and Exposition. https://doi.org/10.1109/ecce.2011.6064328
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.