CoChat

A 650 V/150 A enhancement mode GaN-based half-bridge power module for high frequency power conversion systems

Passmore, B., Storkov, S., McGee, B., Stabach, J., Falling, G., Curbow, A., Killeen, P., Flint, T., Simco, D., Shaw, R., Olejniczak, K. · 2015 · 2015 IEEE Energy Conversion Congress and Exposition (ECCE)
Cited by 40

The DOI matches its Crossref record.

Abstract

Over the past decade, wide bandgap power devices have demonstrated superior electrical and thermal characteristics over Si-based devices at not only the die level but also when integrated into systems. In this paper, a high current 650 V GaN-based power module is presented for high frequency, high power conversion systems. The design and key features of the GaN-based power module are discussed. Both the thermal and electrical characteristics of the GaN-based power module were modeled to estimate the junction-to-case thermal resistance, power loop inductance, and power loop resistance. In addition, the on-state curves, on-resistance, and drain leakage were measured as a function of temperature. The dynamic characteristics were measured to evaluate the fidelity of the transient voltage and current waveforms, switching speeds, and estimate the switching energy losses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/ecce.2015.7310298

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Passmore, B., Storkov, S., McGee, B., Stabach, J., Falling, G., Curbow, A., Killeen, P., Flint, T., Simco, D., Shaw, R., & Olejniczak, K.
Venue
2015 IEEE Energy Conversion Congress and Exposition (ECCE)
Publisher
IEEE
Published
2015-09
Pages
4520-4524
OpenAlex
W1904103275
Cited by
40
References
0
FWCI
2.90
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.