Evaluation of Parameter Variations of Equivalent Circuit Model of Lithium-ion Battery under Different SOH Conditions
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
This paper studies the patterns of equivalent circuit model (ECM) parameter variations under different state-of-health (SOH) conditions for lithium-ion battery. An ECM is constructed in this paper to characterize the ageing behavior of battery by fitting ECM to experimentally measured EIS data within the frequency range from 0.01 Hz to 7.928 kHz. The experimentally measured EIS and SOH data are obtained from an accelerated ageing experiment of lithium-ion battery conducted in the laboratory. The comparison between the EIS data generated from the constructed ECM and experimentally measured EIS data validates the constructed ECM. The variations of the parameters of the ECM as a function of the changes in the SOH of the battery showed that as the battery's health deteriorates overtime, the value of series resistor of the ECM increases and the values of the capacitance components of CPE of the ECM decrease. The presented model and its results can provide a way to estimate or co-estimate the SOH of the battery.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Te aging trials found that this approach signifcantly reduces the amount of time needed to collect data by only requiring half of the data from the aging fndings.”
Citations
Cites
Battery Management System: An Overview of Its Application in the Smart Grid and Electric Vehicles
Rahimi-Eichi, H., Ojha, U., Baronti, F., & Chow, M.-Y. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2250351 · Cited by 960 · cited 4×
“Lithium-ion battery energy storage systems have been widely adopted in the EVs [1-16].”
BackgroundInfluentialA review of state-of-charge indication of batteries by means of a.c. impedance measurements
Rodrigues, S., Munichandraiah, N., & Shukla, A. K. (2000) · Journal of Power Sources · doi:10.1016/s0378-7753(99)00351-1 · Cited by 436 · cited 8×
“Electrochemical impedance spectroscopy (EIS) is an effective analytical technique which can help to gain insight on the electrochemical mechanisms of battery [10-13].”
BackgroundMethodInfluentialCharacterizing aging effects of lithium ion batteries by impedance spectroscopy
Tröltzsch, U., Kanoun, O., & Tränkler, H.-R. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2005.02.148 · Cited by 427 · cited 3×
“Compared with directly utilizing EIS data to estimate the internal state of battery, the ECM method uses a few parameters to store EIS data for internal state estimation [18].”
BackgroundMethodOn the physical interpretation of constant phase elements
Shoar Abouzari, M. R., Berkemeier, F., Schmitz, G., & Wilmer, D. (2009) · Solid State Ionics · doi:10.1016/j.ssi.2009.04.002 · Cited by 383 · cited 1×
“The impedance for this capacitor is given by Equation (1) [22].”
MethodHuang, W., & Abu Qahouq, J. A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2363817 · Cited by 323
Lithium-Ion Battery State-of-Health Estimation Using the Incremental Capacity Analysis Technique
Stroe, D.-I., & Schaltz, E. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2955396 · Cited by 214 · cited 5×
“Lithium-ion battery energy storage systems have been widely adopted in the EVs [1-16].”
BackgroundInfluentialQahouq, J. A. A., & Xia, Z. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2686324 · Cited by 174 · cited 5×
“Lithium-ion battery energy storage systems have been widely adopted in the EVs [1-16].”
BackgroundMethodSelf-citationStroe, D., Swierczynski, M. J., Stan, A.-I., Knap, V., Teodorescu, R., & Andreasen, S. J. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954027 · Cited by 149 · cited 2×
“It is responsible for one of two semi-circles in the EIS [21].”
BackgroundWeng, C., Sun, J., & Peng, H. (2015) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2014.2364554 · Cited by 65 · cited 6×
“Electrochemical impedance spectroscopy (EIS) is an effective analytical technique which can help to gain insight on the electrochemical mechanisms of battery [10-13].”
BackgroundInfluentialCao, Y. F., & Qahouq, J. A. A. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2018.5474 · Cited by 48 · cited 4×
“Lithium-ion battery energy storage systems have been widely adopted in the EVs [1-16].”
BackgroundInfluential
Research works printed but not linked: 3
- 0, Gamry Echem Analyst software, Gamry Instruments
- 0, Tenergy cylindric Lithium-ion cell 30005-0 datasheet
- 0, The Interface 5000E™ potentiostat, Gamry Instruments
Cited by
Online estimation of SOH for lithium-ion battery based on SSA-Elman neural network
Guo, Y., Yang, D., Zhang, Y., Wang, L., & Wang, K. (2022) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-022-00261-y · Cited by 185
“At the same time, the internal parameters of the battery change with time, and this cannot be reflected in the equivalent model, and thus the model cannot respond well to a fluctuation of capacity [23].”
BackgroundA Comprehensive Review on Lithium-Ion Battery Lifetime Prediction and Aging Mechanism Analysis
Madani, S. S., Shabeer, Y., Allard, F., Fowler, M., Ziebert, C., Wang, Z., Panchal, S., Chaoui, H., Mekhilef, S., Dou, S. X., et al. (2025) · Batteries · doi:10.3390/batteries11040127 · Cited by 171
Sun, X., Zhang, Y., Zhang, Y., Wang, L., & Wang, K. (2023) · Energies · doi:10.3390/en16155682 · Cited by 141
Niri, M. F., Rashid, M., Sansom, J. E. H., Sheikh, M. A., Widanage, D., & Marco, J. (2022) · Journal of Energy Storage · doi:10.1016/j.est.2022.106295 · Cited by 136
“Example researches include EIS measurements combined with fuzzy logic algorithms for SoH characterisation of cells as addressed in [30, 31] and regression models based on twelve Li-ion cells EIS spectrum developed in [32].”
State of Health Estimation Methods for Lithium-Ion Batteries
Nuroldayeva, G., Serik, Y., Adair, D., Uzakbaiuly, B., & Bakenov, Z. (2023) · International Journal of Energy Research · doi:10.1155/2023/4297545 · Cited by 138
“According to Xia and Abu Qahouq, the data on electrochemical impedance was collected during the accelerated ageing of the battery [72].”
Metadata
- Authors
- Xia, Z., & Abu Qahouq, J. A.
- Affiliations
- University of Alabama (US)
- ORCID
- Xia, Zhiyong
- Venue
- 2020 IEEE Energy Conversion Congress and Exposition (ECCE)
- Publisher
- IEEE
- Published
- 2020-10-11
- Pages
- 1519-1523
- OpenAlex
- W3096526698
- Cited by
- 41
- References
- 23
- Citations by year
- 2026: 5 · 2025: 9 · 2024: 8 · 2023: 9 · 2022: 9 · 2021: 1
- FWCI
- 3.91
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Physical Sciences › Engineering › Automotive Engineering › Battery Modeling and Management
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Battery Materials
- Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
- Keywords
- lithium-ion batteries, equivalent circuit model, health status (engineering condition monitoring), battery degradation, accelerated aging, electrochemical impedance spectroscopy, model parameter variation, series resistance, constant phase element
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.