A Fault Diagnosis Method for Microservices Based on Multi-Factor Self-Adaptive Heartbeat Detection Algorithm
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Microservice architecture is widely adopted by the current Internet application systems. How to detect faults in microservices effectively and locate them accurately is one of the key problems to guarantee the reliability and performance of microservice systems. This paper combined the use of heartbeat detection mechanism in distributed systems and the characteristics of microservice, put forward a fault diagnosis method for microservices based on multi-factor self-adaptive heartbeat detection algorithm (M-MFSA-HDA). The algorithm uses pull mode heartbeat detection mechanism, combines three factors and can adjust the transmission frequency of heartbeat messages adaptively by giving the optimal solution of it when detecting the failure of microservices. Finally, this paper simulated the algorithm, verified the effect of multiple factors on self-adaptive adjustment of the frequency of sending heartbeat messages and the performance of the algorithm is better than heartbeat detection algorithm based on push mode or which based on pull mode but only considers network factor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The heartbeat mechanism has also been explored as an active probing strategy, sending requests to services and raising alerts when responses are delayed or missing [101]”
From Anomaly detection and root-cause identification in microservices: a survey (2026) · cites this paper as [101]
Citations
Cites
Unreliable failure detectors for reliable distributed systems
Chandra, T. D., & Toueg, S. (1996) · Journal of the ACM · doi:10.1145/226643.226647 · Cited by 2,513 · cited 2×
“Therefore, the following parameters are defined, as shown in Table III: In Table III, both TC and TA contain TA-D and TN-D, all TA, TA-D and TN-D should be big enough to avoid misjudging the detected microservice as failure under normal conditions, and TC should be small enough, so in order to balance K, the expressio…”
Queueing Systems. Volume 1: Theory
Kleinrock, L. (1975) · Cited by 1,972
On the quality of service of failure detectors
Chen, W., Toueg, S., & Aguilera, M. K. (2002) · IEEE Transactions on Computers · doi:10.1109/12.980014 · Cited by 361
Self-citationA Survey on Fault-Tolerance in Distributed Network Systems
Xiong, N. N., Yang, Y., Cao, M., He, J., & Shu, L. (2009) · doi:10.1109/cse.2009.497 · Cited by 17 · cited 1×
“And heartbeat detection algorithm is one of the most commonly used fault detection methods in distributed systems [7].”
MethodGatev, R. (2021) · Apress eBooks · doi:10.1007/978-1-4842-6998-5_1 · Cited by 17
Bahsoon, R. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15114-9_52 · Cited by 12 · cited 1×
“When dealing with the same request task, the occupancy rate of CPU is inversely proportional to the CPU frequency [13].”
BackgroundA methodology to design arbitrary failure detectors for distributed protocols
Baldoni, R., Hélary, J.-M., & Tucci-Piergiovanni, S. (2007) · Journal of Systems Architecture · doi:10.1016/j.sysarc.2007.11.002 · Cited by 4 · cited 1×
“Most studies used the following two basic index to evaluate the performance of heart fault detection [14]:”
Method
Research works printed but not linked: 9
- naohiro, 2004, The ? accrual failure detector[C], Proc IEEE International Symposium on Reliable Distributed Systems, 66
- benjamin, 2008, A lazy monitoring approach for heartbeat-style failure detectors[C], Proceedings of International Conference on Availability Reliability and Security, 404
- kleinrock, 1962, Queueing Systems, 1
- parmar, 2014, Microservice Architecture - A Quick Guide
- yang, 2017, The Application of Micro Service Architecture in Container Cloud[J], Computer & Telecommunication, 7, 79
- wang, 2017, Fault Diagnosis for Microservices with Execution Trace Monitoring [J], Journal of Software, 28, 1435
- wang, 2013, Fault detector of fault-tolerant distributed systems based on self-adaptive heartbeat algorithm [J], Journal of Beijing University of Aeronautics and Astronautics, 39, 952
- zhang, 2016, Application Framework Based on Microservice[J], Computer System and Applications, 25, 265
- hong, 2018, Business System Design and Implementation Based on Microservice Architecture[J], Computer and Digital Engineering, 46, 149
Cited by
Soldani, J., & Brogi, A. (2023) · ACM Computing Surveys · doi:10.1145/3501297 · Cited by 256
“All the surveyed techniques (but for those based on SLO checks [18, 19, 25, 42, 77] or on heartbeating [93]) rely on processing data collected in training runs of the target applications.”
BackgroundMethodAnomaly Detection in Microservice-Based Systems
Nobre, J., Pires, E. J. S., & Reis, A. (2023) · Applied Sciences · doi:10.3390/app13137891 · Cited by 34
Proactive Fault Tolerance using Heartbeat Strategy for Fault Detection
(2019) · International Journal of Engineering and Advanced Technology · doi:10.35940/ijeat.a2079.019119 · Cited by 2
Analysis of Fault Tolerance Techniques in Virtual Machine Environment
Prakash, S., & Vyas, V. (2022) · Lecture notes in networks and systems · doi:10.1007/978-981-16-5655-2_12 · Cited by 2
Anomaly detection and root-cause identification in microservices: a survey
Barata, L. M., Sequeira, S., Lopes, E., Inácio, P. R. M., & Freire, M. M. (2026) · Cluster Computing · doi:10.1007/s10586-026-06095-9 · Cited by 4
“The heartbeat mechanism has also been explored as an active probing strategy, sending requests to services and raising alerts when responses are delayed or missing [101].”
Metadata
- Authors
- Zang, X., Chen, W., Zou, J., Zhou, S., Lisong, H., & Ruigang, L.
- Affiliations
- State Grid Corporation of China (China) (CN)
- North China Electric Power University (CN)
- CAS. Chinese Academy of Sciences, Institute of Information engineering, Beijing, China
- Venue
- 2018 2nd IEEE Conference on Energy Internet and Energy System Integration (EI2)
- Publisher
- IEEE
- Published
- 2018-10
- Pages
- 1-6
- OpenAlex
- W2905936471
- Cited by
- 7
- References
- 7
- Citations by year
- 2026: 1 · 2023: 1 · 2022: 2 · 2021: 1 · 2019: 2
- FWCI
- 0.62
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Conference on Energy Internet and Energy System Integration (EI2) (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Networks and Communications › Software System Performance and Reliability
- Physical Sciences › Computer Science › Computer Networks and Communications › Distributed systems and fault tolerance
- Physical Sciences › Computer Science › Information Systems › Cloud Computing and Resource Management
- Keywords
- microservices, fault diagnosis, heartbeat detection, self-adaptive algorithms, fault detection, distributed systems, fault location
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Fault Diagnosis Method for Microservices Based on Multi-Factor Self-Adaptive Heartbeat Detection Algorithm. https://app.cochat.ai/papers/10.1109/ei2.2018.8582217
- The paper
- Zang, X., Chen, W., Zou, J., Zhou, S., Lisong, H., & Ruigang, L. (2018). A Fault Diagnosis Method for Microservices Based on Multi-Factor Self-Adaptive Heartbeat Detection Algorithm. 2018 2nd IEEE Conference on Energy Internet and Energy System Integration (EI2). https://doi.org/10.1109/ei2.2018.8582217
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.