The detection of Freezing of Gait in Parkinson's disease patients using EEG signals based on Wavelet decomposition
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Freezing of Gait (FOG) is one of the most disabling gait disturbances of Parkinson's disease (PD). The experience has often been described as "feeling like their feet have been glued to the floor while trying to walk" and as such it is a common cause of falling in PD patients. In this paper, EEG subbands Wavelet Energy and Total Wavelet Entropy were extracted using the multiresolution decomposition of EEG signal based on the Discrete Wavelet Transform and were used to analyze the dynamics in the EEG during freezing. The Back Propagation Neural Network classifier has the ability to identify the onset of freezing of PD patients during walking using these features with average values of accuracy, sensitivity and specificity are around 75 %. This results have proved the feasibility of utilized EEG in future treatment of FOG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable Assistant for Parkinson’s Disease Patients With the Freezing of Gait Symptom
Bachlin, M., Plotnik, M., Roggen, D., Maidan, I., Hausdorff, J. M., Giladi, N., & Troster, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036165 · Cited by 693 · cited 1×
“A wearable device using on-body acceleration sensors to measure the patients’ movement has been developed [9].”
Method
Cited by
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 426
Rodríguez-Martín, D., Samà, A., Pérez-López, C., Català, A., Moreno Arostegui, J. M., Cabestany, J., Bayés, À., Alcaine, S., Mestre, B., Prats, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171764 · Cited by 237
Camps, J., Samà, A., Martín, M., Rodríguez-Martín, D., Pérez-López, C., Moreno Arostegui, J. M., Cabestany, J., Català, A., Alcaine, S., Mestre, B., et al. (2018) · Knowledge-Based Systems · doi:10.1016/j.knosys.2017.10.017 · Cited by 224
Toward a Wearable System for Predicting Freezing of Gait in People Affected by Parkinson's Disease
Demrozi, F., Bacchin, R., Tamburin, S., Cristani, M., & Pravadelli, G. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2952618 · Cited by 86
“Other approaches to detect pre-FoG [25], [26] were based on the recognition of EEG pattern [27], the analysis of data gathered by wearable sensors [10], electrocardiography and skin-conductance [12], [18].”
MethodIncreasing fall risk awareness using wearables: a fall risk awareness protocol
Danielsen, A., Olofsen, H., & Bremdal, B. A. (2016) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2016.08.016 · Cited by 66
Metadata
- Authors
- Handojoseno, A. M. A., Shine, J. M., Nguyen, T. N., Tran, Y., Lewis, S. J. G., & Nguyen, H. T.
- Venue
- 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2012-08
- Volume
- 2012
- Pages
- 69-72
- OpenAlex
- W2023507165
- Cited by
- 88
- References
- 1
- FWCI
- 30.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.