Estimating maximal measurable performance for automated decision systems from the characteristics of the reference standard. application to diabetic retinopathy screening
The DOI matches its Crossref record.
Abstract
We investigate the maximal performance that can be measured for automated binary decision systems in terms of area under the ROC curve (AUC), against a reference standard provided by human readers. The goal is to determine the required characteristics of the reference standard to assess and compare automated decision systems with a given degree of confidence, or, to determine what degree of confidence can be obtained given the characteristics of the reference standard. We modeled the expected value of the AUC that can be measured for a perfect decision system, given a reference standard provided either by a single human reader or by multiple human readers (consensus, majority vote). The proposed model was applied to diabetic retinopathy screening in a dataset of 874 eye fundus examinations graded by three readers. The expected value of the AUC for a perfect decision system was estimated at 0.956 against a single human reader, and 0.990 against a `majority wins' vote of three human readers. The Iowa detection program has reached the maximal performance measurable by a single human reader (0.929, CI: [0.897-0.962]) and is close to the maximal performance measurable by a `majority wins' vote (0.955, CI: [0.939-0.972]).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Self-citationAbràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Self-citationDeep learning in ophthalmology: The technical and clinical considerations
Ting, D. S. W., Peng, L., Varadarajan, A. V., Keane, P. A., Burlina, P. M., Chiang, M. F., Schmetterer, L., Pasquale, L. R., Bressler, N. M., Webster, D. R., et al. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2019.04.003 · Cited by 534
Self-citationvan der Heijden, A. A., Abramoff, M. D., Verbraak, F., van Hecke, M. V., Liem, A., & Nijpels, G. (2018) · Acta Ophthalmologica · doi:10.1111/aos.13613 · Cited by 296
“This low agreement is relevant because a larger disagreement between the experts decreases the measurable performance of algorithms (Quellec & Abramoff 2014).”
BackgroundA data-driven approach to referable diabetic retinopathy detection
Pires, R., Avila, S., Wainer, J., Valle, E., Abramoff, M. D., & Rocha, A. (2019) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2019.03.009 · Cited by 164
Self-citation
Metadata
- Authors
- Quellec, G., & Abramoff, M. D.
- Venue
- 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2014-08
- Volume
- 2014
- Pages
- 154-157
- OpenAlex
- W2333579097
- Cited by
- 13
- References
- 0
- FWCI
- 3.46
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimating maximal measurable performance for automated decision systems from the characteristics of the reference standard. application to diabetic retinopathy screening. https://app.cochat.ai/papers/10.1109/embc.2014.6943552
- The paper
- Quellec, G., & Abramoff, M. D. (2014). Estimating maximal measurable performance for automated decision systems from the characteristics of the reference standard. application to diabetic retinopathy screening. 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2014.6943552
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.